Temco Tool DV1200N/P Indoor Fireplace User Manual


 
20
Temco DV1000/1200/1400 Series
76657
Simpson Dura-Vent Venting
Horizontal or Vertical Terminations
The Simpson Dura-Vent Direct Vent System (GS 4”
x 6⁵⁄₈”) offers a complete line of component parts for
installation of both horizontal and vertical installations.
Many items are offered in decorative black, as well as
galvanized finish. The galvanized finish may be used
for installation with your Temco gas fireplace.
The minimum components required for a basic horizon-
tal termination are:
1 Horizontal Termination Cap
1 Flue Adapter (45° Elbow)
1 Wall Penetration Heat Shield
1 Length of pipe to suit wall thickness (see chart)
Wall thickness is measured from the back of the fire-
place to the inside mounting surface of termination cap.
For siding (other than vinyl) furring strips may be used,
instead of the vinyl siding standoff, to create a level
surface to mount the vent terminal. The Terminal must
not be recessed into siding. Measure the wall thickness
including furring strips.
If a Vinyl Siding Standoff is required (it must be used
with vinyl siding), measure to outside surface of wall
without siding and add 2” (51 mm).
Flat Wall Installation (All Units)
Wall Thickness Vent Length
inches (mm) Required (inches(mm))
5
¹⁄₂” - 7” -
(140 - 178 mm) -
9¹⁄₂” - 11” 6”
(241 - 279 mm) (152 mm)
12¹⁄₂” - 14” 9”
(318 - 356 mm) (229 mm)
15¹⁄₂” - 17” 12”
(394 - 432 mm) (305 mm)
14¹⁄₂” - 19⁵⁄₈ 11” - 14⁵⁄₈” Adj. Pipe
(368 - 499 mm) (279 - 372 mm)
20¹⁄₂” - 29” 17” - 24” Adj. Pipe
(520 - 737 mm) (432 - 610 mm)
Corner Installation (DV1000)
2³⁄₄” - 4¹⁄₄ 6”
(70 - 108 mm) (152 mm)
5³⁄₄” - 7¹⁄₄ 9”
(146 - 184 mm) (229 mm)
9³⁄₄” - 11¹⁄₄ 6” + 9”
(248 - 286 mm) (152 mm + 229 mm)
12³⁄₄” - 14¹⁄₄ 6” + 12” / 9” + 9”
(324 - 362 mm) (152 + 305 mm) (229 + 229 mm)
13³⁄₄” - 22¹⁄₄ 17” - 24” Adj. Pipe
(349 - 565 mm) (432 - 610 mm)
7³⁄₄” - 12⁷⁄₈ 11” - 14⁵⁄₈” Adj. Pipe
(197 - 327 mm) (279 - 372 mm)
Corner Installation (DV1200)
2³⁄₁₆” - 3¹¹⁄₁₆ 6”
(56 - 94 mm) (152 mm)
5³⁄₁₆” - 6¹¹⁄₁₆ 9”
(132 - 170 mm) (229 mm)
8³⁄₁₆” - 9¹¹⁄₁₆ 12”
(208 - 246 mm) (305 mm)
9³⁄₁₆” - 10¹¹⁄₁₆ 6” + 9”
(233 - 272 mm) (152 + 229 mm)
12³⁄₁₆” - 13¹¹⁄₁₆ 6” + 12” / 9” + 9”
(310 - 347 mm)
(152 + 229 mm)/ (229 + 229 mm)
13³⁄₁₆” - 21¹¹⁄₁₆ 17” - 24” Adj. Pipe
(335 - 551 mm) (432 - 610 mm)
7³⁄₁₆” - 12⁵⁄₁₆ 11” - 14⁵⁄₈” Adj. Pipe
(183 - 313 mm) (279 - 372 mm)
Corner Installation (DV1400)
7¹⁄₈” - 8⁵⁄₈ 6” + 9”
(181 - 219 mm) (152 + 229 mm)
10¹⁄₈” - 11⁵⁄₈ 6” + 12” / 9” + 9”
(257 - 295 mm) (152 + 229 mm)/(229 + 229 mm)
11¹⁄₈” - 19⁵⁄₈ 17” - 24” Adj. Pipe
(283 - 499 mm) (432 - 610 mm)
5¹⁄₈” - 10¹⁄₄ 11” - 14⁵⁄₈” Adj. Pipe
(130 - 260 mm) (279 - 372 mm)