Superior SDV35 Indoor Fireplace User Manual


 
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
31
Figure 57
Burner Flame Appearance
Model SDV35
1. Locate adjustment rod and adjust air shutter to the standard setting
as shown in Figure 56 (adjustment rod is located in the lower control
compartment).
Note: Move the adjustment rod down to decreases air and up to
increases.
2. Light appliance (follow lighting procedure on lighting label in control
compartment or see care and operation manual).
3. Allow the burner to operate for at least 15 minutes while observing
the flame continuously to ensure that the proper flame appearance
has been achieved (see Figure 57). If the following conditions are
present, adjust accordingly.
• Ifameappearsweakorsooty,adjustairshutter,incrementally,toa
more open position until the proper flame appearance is achieved.
• Ifamestaysloweredblue,adjustairshutter,incrementally,toamore
closed position until the proper flame appearance is achieved.
4. Leave the control knob (off/pilot/on) in the ON position and the burner
OFF/ON switch OFF (and remote switches, if applicable).
5. When satisfied that the burner flame appearance is normal, re-install the
lower control compartment door then proceed to finish the installation.
WARNINGS
Air shutter adjustment should only be performed
by a qualified professional service technician.
Ensure front glass panel are in place and sealed
during adjustment.
CAUTIONS
Soot will be produced if the air shutter is closed
too much. Any damage due to carboning result-
ing from improperly setting the air shutter is n
ot covered under the warranty.
The air shutter door and nearby appliance surfaces
are hot. Exercise caution to avoid injury while
adjusting flame appearance.
Burner Air Shutter Adjustment Procedure
Main Burner Factory Air Shutter
Opening Setting - Inches (millimeter)
Model Natural
Gas
Propane
Gas
SDV35
1/4
(6.35 mm)
1/2
(12.7 mm)
Adjustment
Rod Up
(Fully Open
Position)
Air Shutter
Adjustment Rod
Down (minimum
air opening
position)
Burner
Tube
Adjustment Setscrew
Ref. Air shutter Patent:
U.S. Pat. 5,553,603
Figure 56 - Burner Air Shutter Adjustment
Step 10. HOOD INSTALLATION
(Refer to Figure 58) All of these appliances must have hoods installed
prior to operating.
Install hood by sliding it into the slots on the lower edge of the cabinet top.
FINISHING REQUIREMENTS - Wall Details
Complete finished interior wall. To install the appliance facing flush with
the finished wall, position framework to accommodate the thickness of
the finished wall (Figure 58).
See Page 5 for Cold Climate Insulation and Page 8 for
Clearances and Hearth Extension Requirements
Combustible Finished
Wall Materials
Top of Appliance
Combustible material may
touch the appliance top
Louvers
Top of Door Frame
Hood must be installed as shown.
3"
(76 mm)
This Area Must
Remain Clear of
Combustible
Materials
1 in. Min.
(25 mm)
Drywall Bracket / Spacer
Top Spacers
Figure 58 - Combustible Wall Framing
Header