FAULT MESSAGES (CONT)
DISPLAYED MESSAGE
CONDITION/INDICATES
CHECK/REPAIR
“Blocked Inlet”
The control system has detected open contacts at
the Blocked Intake air pressure switch - inadequate
supply of intake (combustion) air.
If the water heater has been installed as a con-
ventional vent appliance - Ensure the intake air
connection screen is not clogged with debris.
See Service Notes - Venting on page 7.
If water heater has been installed as a direct
vent appliance - check for restrictions, too many
equivalent feet, or too many elbows in the intake
air piping. Review venting installation section of
the Instruction Manual that came with the water
heater - see Table 1 on page 7 in this manual.
Ensure the vent/intake air piping has been
installed within manufacturers requirements.
If water heater has been installed as a direct
vent appliance - temporarily disconnect the
intake air pipe at the blower connection on the
water heater - ensure the screen inside the
intake air connection was removed during
installation. See the Service Notes for venting
on page 7.
Check all wiring between the Blocked Intake air
pressure switch and the CCB’s J6 Socket (page
36) pins 4 & 14. Perform close visual inspection
of the pins inside the plug and socket - ensure
plugs and sockets are mating properly and pro-
viding good contact. Repair/replace anything
worn or damaged.
Review the air pressure switch information
beginning on page 18. Perform the pressure
switch test procedure for the Blocked Intake air
pressure switch - see pages 21 through 23.
Replace the Blocked Intake switch if defective.
Call the technical support phone number shown
on the water heater labeling for further assis-
tance if the problem has not been corrected
after performing the procedures outlined here.