Regency G36D-NG NATURAL GAS Indoor Fireplace User Manual


 
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 27
10) Place the embers on the front of the burner tray in the places shown
on the photos below.
11) Test fi re to ensure proper light off (make sure fl ame fl ows smoothly
from one end of burner to the other). If there is any fl ame hesitation,
check that area for any blockage of the burner ports.
12) Install fl ush glass as per instructions in manual.
Do not block the burner holes in this area
adjacent to the Log 02-54
Place embers in these 3 locations
on the burner tray.
02-54
02-51
02-54
02-55
02-51
02-53
02-50
02-55
02-75
INSTALLATION