F. Burn Rates and Operating Efciency
For maximum operating efciency
1. Thisappliancehasatimersystem(ACC)thatoperates
thestoveatitsmaximumefciencyremovinganyguess
workforthehomeowner.Followtheinstructionsbelow
foreachburnratefortheStart-UpAirControlandBurn
RateAirControl.Figure 22.1.
2. Burndry,well-seasonedwood.
Burn Rates
1. Starting a Fire and Reloading
Open bothcontrols fullyby raising theBurn RateAir
ControlallthewayupuntilitstopsandslidetheStart-up
AirControlbackuntilitstops.Afterloadingthestovewith
woodandstartingthere,setbothcontrolstothedesired
settingbyfollowingtheburnrateinstructionsbelow.
2. High Burn Rate - Maximum Heat
RaisetheBurnRateAirControlallthewayupuntilitstops
(topmarker)toafullyopenposition.SlidetheStart-UpAir
Controlallthewaybackuntilitstops(HImarker)andleave
itthere.Thissettingover-ridesthetimersystem(ACC)so
youmustmonitortherecloselywhileinthissetting.
3.
Medium-High Burn Rate - 15,000 to 30,000 BTU/hr
RaisetheBurnRateAirControlallthewayupuntilit
stops(top marker)toa fullyopen position.Slide the
Start-UpAirControlallthewaybackuntilitstops(HI
marker)andthenpullforwarduntilitstops.Thisactivates
thetimersystem(ACC).
2. Burn Rate Air Control
Thisairsupplyentersattheupperfrontoftherebox,nearthe
topoftheglassdoor.Thispreheatedairsuppliestheneces-
saryfreshoxygentomixwiththeunburnedgases,helping
tocreatesecond,thirdandfourthcombustions.Thisairis
regulatedbytheBurnRateAirControl.Therearefoursettings
High,Medium-High,Medium-LowandLow.Whenthecontrol
israisedallthewayupitisontheHighsettingandwhen
pushedallthedownitisontheLowsetting.Figure 22.1.
NOTE:
Theseareapproximatesettings,andwillvarywith
typeof wood or chimney draft. Due to altitude and other
environmentalcircumstances,thisoperationalinformationis
aguidelineonly.
WARNING
Risk of Fire.
WhensetonHighBurnRateandover-riding
theAutomaticCombustionControlsysteman
overresituationcanoccurandmayresultina
chimneyre.
Overringwillvoidthestovewarranty.
4.
Medium-Low Burn Rate - 10,000 to 15,000 BTU/hr
RaisetheBurnRateAirControluptothebottomof
themiddlemarkerandstop.SlidetheStart-UpAir
Controlallthewaybackuntilitstops(HImarker)and
thenpullforwarduntilitstops.Thisactivatesthetimer
system(ACC).
5. Low Burn Rate - Below 10,000 BTU/hr
LeavetheBurnRateAirControlatthebottommarker.
SlidetheStart-UpAirControlallthewaybackuntilit
stops(HImarker)andthenpullforwarduntilitstops.
Thisactivatesthetimersystem(ACC).
Figure 22.1
NOTE: OperateapplianceonHighBurn15minutesa
daytohelpkeepue/chimneyclean.
START-UP
REAR AIR
HI
Closed
Wide
Open
“HI” setting
over-rides
Timer
Afteractivatingthetimer(ACC),ifthecontrolisplaced
withintherearairsectiononthelabelitwillallowrearair
toentertherebox.Thiswillnotinterferewiththetimer
graduallyclosingthefrontairchannelin25minutes.If
controlisseton“HI”itover-ridesthetimer(ACC).
High (Open)
Low (Closed)
Start-Up Air
Control
Burn Rate
A
ir Control
Front Air Channel
Operated by Timer
Rear Air Channel
Operates independently
from Timer
HIGH
LOW
Timer
Timer Manual
Shut-off
Shown with Side
Shield Removed