2100 Millennium Wood Stove (ACC)
6
Mobile Home Installation
10. Burn wood only. Other types of fuelsmay generate
poisonousgases(e.g.,carbonmonoxide).
11. If unit burns poorly while an exhaust blower ison in
home,(i.e.,rangehood),increasecombustionair.
12. InstallationshallbeinaccordancewiththeManufacturers
Home&SafetyStandard(HUD)CFR3280,Part24.
1. AnoutsideairinletmustbeprovidedforcombustionSee
page 12forinstallationinformation.
2. Appliancemustbesecuredtothemobilehomestructure
by bolting the pedestal through hearth pad and into
oor.
3. Appliance must be grounded with #8 solid copper
groundingwireorequivalentandterminatedateachend
withN.E.C.approvedgroundingdevice.
4. AppliancemustbeinstalledwithanapprovedUL103HT
ventilatedchimney connector,UL103HT chimney,and
terminalcapwithsparkarrestor.Neveruseasinglewall
connector(stovepipe)inamobilehomeinstallation.Use
onlydouble-wallconnectorpipe,Dura-VentDVL,Selkirk
metalbestosDSorSecurityDLdouble-wallconnectoror
anylisteddouble-wallconnectorpipe.
5.
InCanada,thisappliancemustbeconnectedtoa6inch
(152mm) factory-builtchimney conformingto CAN/ULC-
629M,STANDARDFORFACTORYBUILTCHIMNEYS.
6. Followthechimneyandchimneyconnectormanufacturer’s
instructionswheninstallingtheuesystemforuseina
mobilehome.
7. Maintainclearancetocombustibles.
8. Floor protection requirements must be followed
precisely.
9. Use siliconeto createan effective vaporbarrier atthe
locationwherethechimneyorothercomponentpenetrates
totheexteriorofthestructure.
You must use a Quadra-Fire Outside Air Kit Part
OAK-ACC and (depending on oor installation, Part
SRV7033-041) for installation in a mobile home.
NOTE: Offsets from the vertical, notexceeding 45°, are
allowedperSection905(a)oftheUniformMechanicalCode
(UMC).Offsetsgreaterthan45°areconsideredhorizontal
andarealsoallowed,providingthehorizontalrundoesnot
exceed75%oftheverticalheightofthevent.Construction,
clearanceandterminationmustbeincompliancewiththe
UMCTable9C.ThisinstallationmustalsocomplywithNFPA
211.
NOTE:Topsectionsofchimneymustberemovabletoallow
maximumclearanceof13.5feet(411cm)fromgroundlevel
fortransportationpurposes.
Figure 18.1
Spark Arestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop
Double wall
connector pipe
Floor Protector
Outside Air Floor Vent
Outside Air
Rear Vent
CAUTION
THESTRUCTURALINTEGRITYOFTHEMOBILEHOME
FLOOR,WALLANDCEILING/ROOFMUSTBEMAIN-
TAINED
DoNOTcutthrough:
• Floorjoist,wall,studsorceilingtrusses.
• Anysupportingmaterialthatwouldaffectthestructural
integrity.
NEVERINSTALLINASLEEPINGROOM.
Consumesoxygenintheroom.
WARNING
Asphyxiation Risk.