Quadra-Fire 21M-ACC Stove User Manual


 
Page12
7039-131H
May 5, 2011
R
2100 Millennium Wood Stove (ACC)
B. Outside Air Kit Installation
1. Removeallmaterialsfrompackingbox.
2. Usinga#2Phillipsscrewdriverattachtheexadapterto
thestoveusing4screws.Figure 12.1.
3. For oor installations, r
emove circular “knock-out” in the
baseofthepedestal.Figure 12.1.
4. Floor & Rear Installation:Cuta4inch(102mm)holein
outsidewalloroortoaccommodateoutsideairpiping.
Use4inch(102mm)aluminummetalexorrigidpiping
todirectlyconnectoutsideairtoapplianceintake.Use
thesuppliedterminationcapwitharodentscreen.Seal
betweenthewall(oroor)andthepipewithsiliconeto
preventmoisturepenetration.
Included in OAK-ACC: Termination cap, (2) wire ties, flex
adapter,andfasteners
Included in SRV7033-041:Coverplateandsealingrope(see
FloorInstallationAlternativebelow,
Figure 12.2)
Items Needed for Installation (not supplied)
• 4inchexaluminumpipe,orifusingalternatematerial,
thenitshallbemadefromdurable,non-combustible,heat
resistantmaterialupto350
o
F.Cutthepipetotherequired
lengthforyourinstallation.
•Phillipsheadscrewdriver
•Siliconesealant
• Drillsandsawsnecessaryforcuttingholesthroughthe
wallorooringinyourhome
Figure 12.1 - Floor & Rear Installation
Asourceofair(oxygen)isnecessaryinorderforcombus-
tionto takeplace. Whatevercombustion airisconsumed
bytheremustbereplaced.Airisreplacedviaairleakage
aroundwindowsandunderdoors.Inhomesthathavetightly
sealeddoorsandwindows,anoutsideairsourceisneeded.
AnoptionalOutsideAirKitisavail
able.
Flex Line
Wire Tie
Wire Tie
Flex Adapter
Termination
Cap
For Floor Installa-
tions Remove
Circular “Knock-Out”
in Base of Pedestal.
WARNING
Donotdrawoutsidecombustionairfrom:
• Wall,oororceilingcavity
• Enclosedspacesuchasanatticorgarage
• Closeproximitytoexhaustventsorchimneys
Fumesorodormayresult
Fire Risk.
Asphyxiation Risk.
Asphyxiation Risk.
Outsideairinletmustbelocatedtopreventblockage
from:
• Leaves
• Snoworice
• Otherdebris
Blockmaycausecombustionairstarvation
Smokespillagemaysetoffalarmsorirritatesensitive
individuals.
WARNING
Asphyxiation Risk.
LengthofoutsideairsupplyductshallNOTexceed
thelengthoftheverticalheightoftheexhaustue.
Firewillnotburnproperly
Smokespillageoccurswhendoorisopeneddueto
airstarvation.
WARNING
Figure 12.2 - Floor Installation Alternative
Cover
Plate
5. Floor Installation Alternative: Insomeinstancesyou
maynotbeabletoinstalltheexpipeasshowinFigure
12.1.Ifthatisthecase,youwillneedtoorderSRV7033-
041 which includes a cover plate and sealing rope as
showninFigure 12.2.Thegoalistosealthepedestal
sonoroomaircanleakintothepedestalandtosealor
forcoldairinltration.