Pelco Manual C1043M-A (2/96) 3
3.0 INSTALLATION
3.1 SETTING UP ICI1000PIM
PARAMETERS AND BENCH
TESTING
NOTE: Please familiarize yourself with the
information in this manual prior to installation
and operation. Contact the customer's register
dealer/installer prior to installation and opera-
tion. Some warranties and/or service agree-
ments may be affected.
1. Set the ICI1000PIM switch settings for your reg-
ister according to the PIM manual (C1005M).
Make sure that switch number 2 on switch bank 1
is placed in the [-] "UP" or “POLLING” position.
Also, you must address each PIM individually;
refer to page #2 in your ICI1000PIM manual.
2. Plug the data (phone-style) cable supplied with the
ICI3000WK between the ICI1000PIM set to ad-
dress #1 and the port labeled DATA IN on the
ICI3000P unit.
3. Connect a coaxial cable between the port labeled
“VIDEO OUT” of the ICI3000P and a CCTV
monitor.
4. Press the [1] one key on your keyboard while pow-
ering up the ICI3000P. The following will be dis-
played on your screen:
!!DEFAULTS LOADED!!
ICI3000P BY PELCO, INC. VER. X.X
CRC = YYYY
CALCULATED CRC = ZZZZ
5. Power up the ICI1000PIM with the supplied trans-
former.
6. Press [P] on the keyboard and the following will
be displayed:
Poll watch on!
7. To verify communication between your
ICI1000PIM and the ICI3000P, press [I] on the
keyboard and the following will be displayed:
Poll initialized!
Reg. polled = 1 1 Reg. answer!
Reg. polled = 2 2 No reg. answer!
Reg. polled = 3 3 No reg. answer! etc.
The display will poll for 32 ICI1000PIM addresses, and
then repeat display the addresses that answer.
8. Stop polling by pressing [P] again. The following
message will be displayed:
Poll watch off!
9. Select the Register PIM by pressing [F1] then [1]
followed by [Reg #] and [ENT].
10. Power down the ICI1000PIM. Power ICI1000PIM
up again.
11. A prompt will appear on the bottom of the screen.
Verify that this prompt matches the description set
forth in the manual supplied with your interface
cable.
12. Repeat these steps for the remainder of your
ICI1000PIM’s
NOTE: Each ICI1000PIM must have a dif-
ferent Polling address. Refer to the ICI1000PIM
manual for proper settings.
13. After polling each ICI1000PIM, power down the
ICI3000P and begin installation of the ICI1000PIM
and cash register interface cable into each cash reg-
ister. Refer to the manual supplied with your inter-
face cable for proper installation.