Omega Vehicle Security OM5-C Electric Heater User Manual


 
9
MODEL INPUT* (rms) OUTPUT* (dc)
OM5-IAC-100B-C 0-100mV 0-5V
OM5-IAC-1B-C 0-1V 0-5V
OM5-IAC-10B-C 0-10V 0-5V
* Modules can be ordered with other input/output ranges. Consult factory for
ordering details and specifications.
ORDERING INFORMATION
Input
Signal Range 100mV to 10V rms, 0 to 5A rms
Standard Frequency Range 45Hz to 1000Hz
Extended Frequency Range 1kHz to 20kHz
Impedance 1 M ±1% shunted by 100pF (-01 thru -05),
0.05 ±1% (-06, -07)
Coupling AC
Protection
(1)
Continuous 480V (Peak AC & DC)
Transient ANSI/IEEE C37.90.1-1989
Output
Signal Range 0-5V
Current Limit 8mA
Voltage Limit ±18V
Resistance 50
Protection Continuous Short to Ground
Ripple and Noise (100Khz) 0.025% Span rms
Accuracy
(2)(3)
Sinusoid
50/60 Hz ±0.25% Span
45Hz to 1kHz ±0.25% Reading Additional Factor
1kHz to 20kHz ±0.75% Reading Additional Factor
Non-Sinusoid
Crest Factor = 1 to 2 ±0.05% Reading Additional Error
Crest Factor = 2 to 3 ±0.15% Reading Additional Error
Crest Factor = 3 to 4 ±0.30% Reading Additional Error
Crest Factor = 4 to 5 ±0.40% Reading Additional Error
Vs. Temperature ±100ppm/°C
Isolation (Common Mode)
Input to Output, Input to Power
Continuous 1500Vrms max
Transient ANSI/IEEE C37.90.1-1989
Output to Power
Continuous 50Vdc max
Rejection (50-60Hz Common Mode) 100dB
Response Time (0 to 99%) <400ms
Output Enable Control
Selection Time 6.0µS @ C
LOAD
= 0 to 2000pF
Voltage
Max Logic “0” +0.8V
Min / Max Logic “1” +2.4V / +36V
Current, “0,1” 0.5µA
Loop Voltage +7.5Vdc min, +26Vdc max
Load Resistance (maximum) (Loop Voltage - 14) / (Loop Current)
Supply Voltage +5VDC ±5%
Current 30mA
Sensitivity ±200ppm/%
Environmental
Operating Temp. Range -40˚ C to +85˚ C
Storage Temp. Range -40˚ C to +85˚ C
Relative Humidity 0 to 90% noncondensing
Emissions EN50081-1, ISM Group 1, Class A (Radiated, Conducted)
Immunity EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)
Dimensions 2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)
NOTE:
(1) Module rating only. Backpanel connector rating may differ — use the lowest of the two in
accordance with required safety requirements.
(2) At standard 60Hz factory calibration. Consult factory for calibration at other frequencies.
(3) For 10-100% rated span. Add an additional 0.25% error for 0-10% Span measurements.
Accuracy includes nonlinearity, hysteresis and repeatability but not source or external shunt
inaccuracy (if used).
SPECIFICATIONS Typical at T
A
= +25°C and +5V power.
Module
OM5-IAC