10-40
Page 48
2008-12-03
disinfectant.
Water installation
Check water the water hoses of the humidifier for
cracks and correct fastening, replace defective hoses.
Carefully clean the hoses with a combined detergent
and disinfectant.
Check water supply line for sealing and seal if
necessary. Dismantle water filter (if present) and clean
it.
Spray Bar Cap
Dismantle the spray bar cap and check the holes in the
water distribution pipes for mineral deposit. If
necessary, dismantle the water distribution pipes and
remove the mineral deposit. Clean spray bar cap and
water distribution pipes with a combined detergent and
disinfectant.
Drain line with Siphon
Check and clean with a combined detergent and
disinfectant, if necessary.
UV water treatment
(Option)
Dismantle the UV lamp. Carefully clean glass tube and
UV lamp. After max. of 8000 operating hours the UV
lamp must be replaced.
Electric installation
Check all cables and components for correct fastening,
correct function and defects. Have defective
components replaced or loose components fastened
by a qualified specialist.