Nortec MH Series Humidifier User Manual


 
10-10
Page 27
2008-12-03
Figure 8. Mounting Process – Step 8
Fix hydraulic unit to the water tub and the cross beam using four hexagon socket screws 1/4 UNC x 1/2"
and washers.
Important: Remove the closing plug “H” from the circulation pump inlet before mounting
the hydraulic units MHB Reflow or MHTC Reflow.