Napoleon Fireplaces BGD36CFGN Indoor Fireplace User Manual


 
47
W415-0661 / C / 02.20.08
Main burner goes out;
pilot stays on.
Pilot fl ame is not large enough or
not engulfi ng the thermopile
- turn up pilot fl ame.
- replace pilot assembly.
Thermopile shorting - clean thermopile connection to the valve. Reconnect.
- replace thermopile / valve.
Remote wall switch wire is too
long; too much resistance in the
system.
- shorten wire to correct length or wire gauge.
Faulty thermostat or switch.
- replace.
Main burner goes out;
pilot goes out.
Refer to "MAIN BURNER GOES OUT; PILOT STAYS ON"
Vent is blocked
Vent is re-circulating
- check for vent blockage.
- check joint seals and installation.
4" fl exible vent has become dis-
connected from fi replace.
- re-attach to fi replace.
- 7"ø cap was not replaced
Pilot will not light. - check if pilot can be lit by a match
- check that the wire is connected to the push button igniter.
- check if the push button igniter needs tightening.
- replace the wire if the wire insulation is broken or frayed.
- replace the electrode if the ceramic insulator is cracked or broken.
- replace the push button igniter.
No spark at pilot burner
- fi ll the tank.
Out of propane gas
Spark gap is incorrect
- spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.) from the electrode
tip and the pilot burner. To ensure proper electrode location, tighten securing nut
(fi nger tight plus 1/4 turn).
No gas at the pilot burner
- check that the manual valve is turned on.
- check the pilot orifi ce for blockage.
- replace the valve.
- call the gas distributor.
Pilot goes out when the
gas knob is released.
The gas valve has
an interlock device
which will not allow
the pilot burner to be
lit until the thermo-
couple has cooled.
Allow approximately
60 seconds for the
thermocouple to
cool.
System is not correctly purged.
- purge the gas line.
Out of propane gas. - fi ll the tank.
Pilot fl ame is not large enough
- turn up the pilot fl ame.
- gently twist the pilot head to improve the fl ame pattern around the thermo-
couple.
Pilot fl ame is not engulfi ng the
thermocouple.
Thermocouple shorting / faulty.
- loosen and tighten thermocouple.
- clean thermocouple and valve connection.
- replace thermocouple.
- replace valve.
Faulty valve.
- replace.
Pilot burning; no gas to
main burner; gas knob
is on 'HI'; wall switch /
thermostat is on.
Themostat or switch is defec-
tive.
- connect a jumper wire across the wall switch terminals; if main burner lights,
replace switch / thermostat.
Main burner orifi ce is plugged. - remove stoppage in orifi ce.
Faulty valve.
- replace.
Wall switch wiring is defective.
- disconnect the switch wires & connect a jumper wire across terminals 1 & 3; if
the main burner lights, check the wires for defects and / or replace wires.
BGD36CF / BGD42CF TROUBLE SHOOTING GUIDE
B
EFORE
ATTEMPTING
TO
TROUBLESHOOT
,
PURGE
YOUR
UNIT
AND
INITIALLY
LIGHT
THE
PILOT
AND
THE
MAIN
BURNER
WITH
THE
GLASS
DOOR
OPEN
.
SYMPTOM PROBLEM TEST SOLUTION
Pilot goes out while
standing; Main
burner is in 'OFF'
position.
Gas piping is undersized. - turn on all gas appliances and see if pilot fl ame fl utters, diminishes or
extinguishes, especially when main burner ignites. Monitor appliance
supply working pressure.
- check if supply piping size is to code. Correct all undersized piping.