Napoleon Fireplaces BGD36CFGN Indoor Fireplace User Manual


 
34
W415-0661 / C / 02.20.08
FIGURE 119
Drywall dust will penetrate into the
blower bearings, causing irrepara-
ble damage. Care must be taken to
prevent drywall dust from coming
into contact with the blower or its
compartment. Any damage resulting
from this condition is not covered by
the warranty policy.
FIGURE 120
Attach the connectors from
the black and white wires to
the thermodisc and secure the
thermodisc bracket to the secur-
ing stud at the bottom left of the
unit using a lock washer and wing
nut. Ensure that the thermodisc
touches the fi rebox wall.
Attach the connectors from
the black and red wires to the
blower.
Attach and secure the vari-
able speed switch using the
nut provided. Plug the har-
ness cord into the receptacle.
Note: To improve access to the variable speed control, we recom-
mend bending the mounting bracket forward by approximately 10°.
The wire harness provided in this kit is a universal harness.
When installed, ensure that any excess wire is contained, pre-
venting it from making contact with moving or hot objects.
To safely install the fan, turn off the electricity fi rst.
If the fi replace was not previously equipped with a fan: route a
grounded 2-wire, 60hz power cable to
the junction box. At this point, it must
be strain relieved and insulated.
The wire harness provided in this
kit is a universal harness. When in-
stalled, ensure that any excess wire is
contained, preventing it from making
contact with moving or hot objects.
To ease installation of the fan, remove
the hinge screen and valve control door (lower louvres) from the
base of the fi replace.
Position the vibration reducing pad into the clip and onto the threaded
stud at the other end, piercing a hole into the pad. The fan assembly
must be able to be positioned entirely onto the pad.
Slide the fan assembly past the controls and into the clip. Secure
using the lock washer and nut provided.
Plug the harness cord into the receptacle.
Attach and secure the sensor assembly bracket to the securing stud
located next to the receptacle/junction box at the bottom left of the
unit using the lock washer and wing nut. Ensure that the thermodisc
touches the fi rebox wall.
Plug the power cord back into the receptacle.
When installed, ensure that any excess wire is contained, preventing
it from making contact with moving or hot objects.
ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED IN-
STALLER and must be connected and grounded in accordance with
local codes. In the absence of local codes, use the current CSA C22.1
C
ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL
ELECTRICAL CODE in the United States.
This optional kit is meant to be used only in conjunction with the
GD65 Fan Kit, shown above, which may be ordered from your Wolf
Steel / Napoleon® dealer.
With the thermostatic sensor option, the fan, when turned on, be-
comes thermally activated, and will automatically run approximately
15-30 minutes after the fi replace has been lit and for approximately
30-45 minutes after the fi replace has been turned off.
Use of the fan increases the output of heat.
Unplug the power cord from the receptacle. Connect all wires as
shown.
OPTIONAL FAN INSTALLATION
GD36 THERMOSTATIC
SENSOR CONTROL
FIGURE 121
FIGURE 123
FIGURE 122
FIGURE 124