Napoleon Fireplaces BGD36CFGN Indoor Fireplace User Manual


 
33
W415-0661 / C / 02.20.08
FIGURE 116
FIGURE 117
A
A
B
B
FIGURE 118a
FIGURE 118a
C
C
FIGURE 118b
FIGURE 118b
INSTALLING THE BLOWER
INSTALLATION TO BE
DONE BY A QUALI-
FIED INSTALLER and
must be electrically con-
nected and grounded in
accordance with local
codes. In the absence
of local codes, use
the current CSA C22.1
C
ANADIAN ELECTRICAL
CODE in Canada or the
ANSI/NFPA 70
NATIONAL
ELECTRICAL CODE in the
United States
If the fireplace was not
previously equipped with
a blower: route a grounded
2-wire, 60hz power cable
to the receptacle / junction
box. At this point, it must
be strain relieved and in-
sulated.
Because the blower is
thermally activated, when
turned on, it will automatically start approximately 10 minutes
after lighting the fi replace and will run for approximately 30-45
minutes after the fi replace has been turned off. Use of the fan
increases the output of heat.
The three slots on the blower mounting bracket allow ease of adjust-
ment when attaching the blower. For a quiet running blower, do not
allow the assembly to sit on the fi rebox base.
Slide the vibration reducing pad (A) into the clip (C) and up against
the threaded stud (B) at the other end. The blower must be able to
be positioned entirely onto the pad.
To ease installation of the blower, remove the hinge screen and valve
control door (lower louvres) from the base of the fi replace.
Tilt the blower onto its side. Slide it past the controls and into the clip
(C). Secure to the threaded stud using the lock washer and wing nut
provided. Ensure that the blower does not touch the fi replace base
or the fi rebox.
5. Remove the 8 perimeter screws as illustrated in Fig. 112a and
lift out the burner base. (The gas line fl ex-connector should pro-
vide suffi cient move-
ment to permit shifting
the burner assembly
to the side).
6. Reverse procedure
to re-assemble.
OPTIONAL BLOWER INSTALLATION
BGD36CF(G) ACCESSING THE BLOWER
1. Remove the valve access door.
2. Open the main door.
3. Carefully remove the logs.
3a. (BGD36CFG) Carefully remove the glass and glass ember
tray.
4. Remove the 7 screws illustrated in Fig. 112a and lift out the log
support.
4a. (BGD36CFG) Remove the top defl ector and porcelain panels
from the fi rebox. (See Figure 109).
FIGURE 112a
FIGURE 112a
FIGURE 112b
FIGURE 112b
BGD42CF ACCESSING THE BLOWER
1. Remove the main door using the instructions on Pg #29.
2. Carefully remove the logs.
3. Remove the grate by lifting it off of the two securing pins.
4. Remove the 6 screws illustrated in Fig. 112b and lift out the
log support. Be careful not to lose the spacers for the screws
indicated.
5. Remove the 7 perimeter screws as illustrated in Fig. 113 and lift
out the burner base. (The gas line fl ex-connector should provide
suffi cient movement to permit shifting the burner assembly to the
side).
6. Reverse procedure to re-assemble.
SPACERS
FIGURE 113
FIGURE 113
FIGURE 114
FIGURE 114