RESTRICTING VERTICAL VENTS
FIGURE 65
BGD42CF ONLY: Vertical terminations may display a very active
fl ame. As this appearance is not desirable, the vent exit must be
restricted using restrictor plate, W500-0205. This reduces the
velocity of the exhaust gases, slowing down the fl ame pattern and
creating a more traditional appearance. The plate has a series of
holes to allow for adjustment.
Remove the two screws on either side of the exhaust collar inside
the fi rebox. Install the plate as shown. Install the plate on the desired
set of holes then replace the screws.
Proceed once the vent installation is complete.
NOTE: All gas connections must be contained within the fi re-
place when complete.
1. Move the fi replace into position and secure to the fl oor through
the 1/4" holes located at either side of the base.
2. The fi replace is designed to accept 3/8" gas supply line. The
fi replace is equipped with a 3/8" manual shut-off valve.
3. Connect the gas supply in accordance to local codes. In the
absence thereof, install according to the National Installation Code.
4. When fl exing any gas line, support the gas valve so that the
lines are not bent or kinked.
5. Check for gas leaks by brushing on a soap and water solu-
tion.
DO NOT USE OPEN FLAME.
Purge all gas lines with the glass door of the stove removed.
Assure that a continuous gas fl ow is at the burner before re-
installing the door.
TOP OF THE
FIREBOX
FLUE COLLAR
RESTRICTOR PLATE
FIGURE 64
GAS INSTALLATION
This appliance may be installed as an OEM (Original Equipment
Manufacturer) Installation in a manufactured home or mobile
home and must be installed in accordance with the manufacturer's
instructions and the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, in the United States or the Mobile
Home Standard, CAN/CSA Z240 MH Series, in Canada. This ap-
pliance is only for use with the type(s) of gas indicated on the rating
plate. A conversion kit is supplied with the mobile home appliance.
This Mobile/Manufactured Home listed appliance comes factory
equipped with means to secure the unit.
The fi replace is equipped with two 1/4" diameter holes located in the
front left and right corners of the base. For mobile home installations,
the fi replace must be fastened in place. Use #10 screws, inserted
through the holes in the base to secure.
Always turn off the pilot and the fuel supply at the source, prior to
moving the mobile home.
After moving the mobile home and prior to lighting the fi replace,
permanently ensure that the logs are positioned correctly.
This appliance may be installed in an aftermarket permanently
located, manufactured (mobile) home, where not prohibited
by local codes.
This appliance is only to be used with the type of gas indicated
on the rating plate. This appliance is not convertible for use
with other gasses, unless a certifi ed kit is used.
CONVERSION KITS
The mobile home appliance is fi eld convertible between Natural Gas
(NG) and Propane (LP).
To convert from one gas to another consult your Napoleon® dealer/
distributor.
MOBILE HOME INSTALLATION
For remote wall switch and decorative light installations for the BGD-
36CFG see section "BGD36CFG SWITCH/WIRING DIAGRAM".
For ease of accessibility, an optional remote wall switch may be
installed in a convenient location. A 20ft length of millivolt wire is
connected to the gas valve for the wall swtich. However, if a greater
length is required route 2-strand (solid core) millivolt wire through the
electrical hole located at the bottom left side of the unit. The recom-
mended maximum lead length depends on wire size:
OPTIONAL WALL SWITCH
INSTALLATION EXCLUDING BGD36CFG
Do not connect either the wall switch, thermostat or gas valve
directly to 110 volt electricity.
WIRE SIZE MAX. LENGTH
14 gauge 100 feet
16 gauge 60 feet
18 gauge 40 feet
Attach the two leads to terminals 1 and 3 located on the gas valve.