Napoleon Fireplaces BGD36CFGN Indoor Fireplace User Manual


 
4
W415-0661 / C / 02.20.08
Maximum inlet gas pressure is 7" water column for natural gas and
13" water column for propane. Manifold pressure under fl ow condi-
tions is 3.5" water column for natural gas and 10" water column for
propane.
This fi replace is approved for bathroom, bedroom and bed-sitting
room installations and is suitable for mobile home installation.
No external electricity (110 volts or 24 volts) is required for the
gas system operation.
Expansion / contraction noises during heating up and
cooling down cycles are normal and are to be expected.
Use only accessories designed for and listed with your specifi c
replace.
Provide adequate ventilation air. Provide adequate accessibil-
ity clearance for servicing and operating the fi replace. Never
obstruct the front opening of the fi replace.
Objects placed in front of the fi replace must be kept a minimum
of 48" away from the front face of the unit.
Do not use abrasive cleaners to clean plated parts. Buff lightly with
a clean dry cloth. The BGD36CF(G) and BGD42CF are factory
equipped with tempered glass. The glass thickness is 3/16" for both
models. Use only replacement glass available from your Napoleon®
dealer. DO NOT SUBSTITUTE MATERIALS. Clean the glass after
the fi rst 10 hours of operation with a recommended gas fi replace
glass cleaner. Thereafter clean as required. DO NOT CLEAN GLASS
WHEN HOT! If the glass is not kept clean permanent discoloration
and / or blemishes may result.
THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY
A QUALIFIED INSTALLER to conform with local codes. Installation
practices vary from region to region and it is important to know the
specifi cs that apply to your area,
for example: in Massachusetts State:
• The fi replace damper must be removed or welded in the open
position prior to installation of a fi replace insert or gas log.
• A carbon monoxide detector is required in all rooms containing
gas fi red appliances
• The appliance off valve must be a “T” handle gas cock.
• The fl exible connector must not be longer than 36".
• The appliance is not approved for installation in a bedroom or
bathroom unless the unit is a direct vent sealed combustion
product.
• WARNING: This product must be installed by a licensed plumber
or gas fi tter when installed within the commonwealth of
Massachusetts.
In absence of local codes, install the BGD36CF(G) and BGD42CF
to the current National Fuel Gas Code, ANSI Z223.1, or the current
CAN/CGA B149, Installation Codes. Mobile home installation must
conform with local codes or in the absence of local codes, install
to the current standard for gas equipped mobile housing CAN/CSA
ZA240 MH Series in Canada or the Manufactured Home Construc-
tion and Safety Standard, Title 24 CFR, Part 3280, or the Fire Safety
Criteria for Manufactured Home Installations, Sites and Communities
Standard ANSI/NFPA 501A in the United States.
The fi replace and its individual shut off valve must be disconnected
from the gas supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 psig (3.5 kPa). The fi replace
must be isolated from the gas supply piping system by closing its
individual manual shut off valve during any pressure testing of the
gas supply piping system at test pressures equal to or less than 1/2
psig (3.5 kPa).
When the fi replace is installed directly on carpeting, vinyl tile or
other combustible material other than wood fl ooring, the fi replace
shall be installed on a metal or wood panel extending the full width
and depth.
If the optional fan or blower is installed, the junction box must be
electrically connected and grounded in accordance with local codes.
In the absence of local codes, use the current CSA C22.1 CANADIAN
ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL
ELECTRICAL CODE in the United States.
All sections with BGD36CF(G) are common to both the BGD36CF
and the BGD36CFG.
FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-
FIRED TO ASSURE ITS OPERATION AND QUALITY!
BGD36CF(G)
Maximum input for the BGD36CF(G) is 17,000 BTU/h for natural
gas and propane. Maximum output for natural gas and propane is
10,900 BTU/hr at an effi ciency of 64% with the fan on. The A.F.U.E.
(annual fuel utilization effi ciency) rating is 53% for natural gas and
propane.
BGD42CF
Maximum input for the BGD42CF is 24,000 BTU/hr for natural gas
and propane. Maximum output for natural gas and propane is
16,000 BTU/hr at an effi ciency of 67% with the fan on. The A.F.U.E.
(annual fuel utilization effi ciency) rating is 61.5% for natural gas and
propane.
When the fi replace is installed at elevations above 4,500ft, and in the
absence of specifi c recommendations from the local authority having
jurisdiction, the certifi ed high altitude input rating shall be reduced at
the rate of 4% for each additional 1,000ft.
Minimum inlet gas supply pressure is 4.5" water column for natural
gas and 11" water column for propane.
GENERAL INSTRUCTIONS
GENERAL INFORMATION
CARE OF GLASS AND PLATED PARTS