3
Specifications
Current & Voltage Ratings
Alarm Output -------------------------- Burg: 12 VDC, 2A (max.)
Output Current Limiting -------------- Burg: 2.25 A
AUX Power: 750 mA
Residential Burglary (4 Hour Standby)
Combined Standby Current: -------- 350 mA
Bell Output: ---------------------------- 2 A
(Using Rechargeable 12 VDC 4 AH BATTERY, minimal requirement)
Transformer and Battery
Required Transformer: -------------- NAPCO TRF12 OR
BASLER 16.5 VAC 20VA
Required Battery: --------------------- 12V 4 AH Rechargeable
Change Battery every 5 years or as required
Maximum Charging Current: ------ 165 mA
Maximum Input Current: ------------- 2.58 A
Loop Characteristics
Loop Voltage: --------------------------5 Volts
Loop Current : --------------------------Zones 1, 2: 0.9 mA (2.2 K)
Zones 3, 4: 0.5 mA (3.9 K)
Loop Resistance: ----------------------100Ω per zone (max.)
Device Specifications
Max # keypads: ------------------------4, RPXP4GT current = 35 mA
Max # of receivers: --------------------2, GEM-RECV-XP8
current = 65 mA each
Max Keypad wire length : ----------1000’ total wire length
Miscellaneous
Housing Dimensions : --------------10
5
/
16
"
x 8
6
/
16
"
x 3"
(26.2 x 21.3 x 7.6) HxWxD
Shipping Weight: ---------------------XP-400/4 15.5 lbs.
Operating Temperature: -------------0-49ºC (32-120°F)