24
WI1370 XP-400 Installation Instructions
Keypad Beeps or
H
SYSTEM
Flashes
Zone LED
ON
System Trouble
Condition
Cause/Action
1 Beep
Y
LED
1
Y
AC Power Failure
This trouble will occur if AC power is not present. Ensure that the transformer is connected to an unswitched power source.
2 Low Battery
If there has been a recent power failure, the battery may be partially depleted and must be recharged by the control panel. If
the trouble does not go away in 24 hours, replace the battery.
3 Communication
Failure/PCPreset Fail
The system was not able to report to central station. Check panel programming and telephone line wiring. The trouble will
clear after it has been acknowledged by viewing the system trouble as long as the telephone line has passed a line cut test
(tested automatically by the panel). The Panel did not sucsessfully connect and download/upload with the commputer
running PCPreset - check Auto Download ID number, Callback Number or PCPreset Setup.
4 Telephone Line Cut
The telephone line has failed. If telephone service has been temporarily interrupted, the trouble will clear when restored and
acknowledged by viewing the system trouble.
2 Beeps 1 Bell/Siren line Cut
There is a problem with the Bell or Siren wiring. EOL2.2K resistor must be installed.
3 Rcvr Fail-to-Respond/Rcvr
Tamper
The receiver is not responding to the panel. The red LED on the receiver should be flashing, refer to WI848. The cover is off
the receiver causing a tamper signal to be transmitted.
4 Receiver Jam
A signal is blocking the normal reception of transmissions from the wireless devices. Ensure that the green LED on the
receiver is not on continuously, refer to receiver manual WI848.
3 Beeps 1-4 Wireless
Transmitter Low Battery
The battery in the wireless transmitter is low and should be replaced. This transmitter is on the zone corresponding to the
number of the zone light flashing. The replacement battery for the GEM Trans2 door/window transmitter and the GEM PIR
wireless motion detector is the Duracell DL123A. (2 required for the GEM-PIR) WARNING: Replace batteries only with the
same type as specified above. Use of another battery may present a risk of fire or explosion. Do not recharge or disassemble
battery or dispose of in fire.
4 Beeps 1-4 Wireless
Transmitter
Supervisory Failure
The panel has not received a supervisory signal from the transmitter within the time programmed. Check Wireless
Supervisory Timer [16] Programming. Check the placement of the transmitter and receiver, refer to WI848.
7 Beeps 1-4 Zone Trouble
The panel has one or more of the following 3 possible troubles: Zone Short, Transmitter Tamper or Dual Tech Self Test Fail.
System Troubles