WI1370 XP-400 Installation Instructions
While in User Program Mode the
W
Armed,
X
READY and
H
System Trouble LEDs will
continue to flash, follow the example below to
program a User 2’s code to 1923.
User Mode Programming Example:
1.Press
2
, Zone 2 LED will Flash
2.Enter
1 9 2 3
, Zone 2 LED will
continue to flash until the 4th digit is
entered. The keypad will beep 4 times
confirming a valid entry (Zone LED steady).
Deleting a User Code
Press the number of the User to be deleted, the
zone LED will be flashing indicating that the user
has been selected. Press the
A4
, the LED
associated with the user will now be OFF.
Exiting User Program Mode
To exit User Program Mode press the
b
key.
XP-600 Commands
User Commands
A 1
Bell Test
Enter this command to turn on the Bell, keypad
sounder and keypad LEDs for 2 seconds. The
battery is tested during a Bell Test, and
automatically every *24 hours to ensure proper
battery operation under load. The Alarm output
requires a battery in order to supply the
specified output. If the battery cannot sustain
the load, a low battery indication will be
displayed. A battery test is also performed on
power-up after a 3 minute delay.
*A battery test occurs every 4 hours when
Household Fire [96-3] has been selected.
CC
Group Bypass
Enter this command to bypass all Exit/Entry
Follower Zones or Home/Away Zones (only if
the system is programmed exclusively for
Home/Away with Delay zones).
A4
Instant
Enter this command before or after arming to
remove the entry delay on Entry/Exit Zones.
The keypad ARMED LED will flicker rapidly.
Faulting a Exit/Entry Zone will result in an
immediate alarm.
A 5
Chime ON/OFF
Enter this command to turn chime ON/OFF.
The Keypad will chime on any zone that has not
been selected as an Exit/Entry Follower Zone,
Home/Away with Delay Zones, or 24 Hour Zone.
A 8
+ User 1 Code - User Program
Mode
A 9
Keypad Sleep Mode ON/OFF
Enter this command to turn the keypad sounder
ON/OFF. When the keypad is in Sleep mode all
keypad sounds will be silenced except for
keypad feedback beeps and Keypad Sounder
on Alarm.
User Commands - Optional
A 0
Easy Exit/Easy Arm
If enabled in Dealer programming, enter this
command while the panel is Armed to allow 3
minutes to exit the premises through Exit/Entry
and Exit/Entry Follower Zones. Enter
a0
to
arm the panel. To disarm the panel a valid Arm/
Disarm code must be entered. Requires Easy
Exit/Easy Arm [21-2] to be enabled.
A 3
Access on PGM
If enabled in Dealer programming, enter this
command to activate the PGM output (Terminal
15) for 5 seconds.
Zone LED Meaning
OFF
User Arm/Disarm Code not programmed
Flashing
User Arm/Code is currently being programmed
Steady
User Arm/Disarm Code has been programmed
TABLE
4
Z
ONE
L
ED
D
EFINITION
-U
SER
P
ROGRAM
M
ODE