16
WI1370 XP-400 Installation Instructions
Pager Alarm data is the same as 4/2 format
with the exception that the 2 digit Report
Code is transmitted before the 4 digit
Subscriber ID.
[33]Receiver Options
(1) 2300 Hz HS/Kissoff
- Select 2300 Hz
Handshake and Kissoff.
(2) Sumcheck - Only used for the following
Receiver Formats: Ademco Slow, Radionics
Fast, Silent Knight Fast and Universal High
Speed. This is a sophisticated data format
used to enhance the speed and check the
accuracy of the received transmission. This
format should be used whenever the central
station has this capability. Instead of
sending a second round to verify correct
data, the panel sends a Sumcheck digit after
sending the Subscriber ID and Alarm Code.
(3) Single Digit
- 3/1 Format. 3-digit
Subscriber ID number and a 1-digit Alarm
Code will be transmitted.
(4) No Handshake/Pager Extend
- The
meaning of this option is dependent on
Receiver Format programming.
No Handshake
(
All receiver formats except Pager
Format)
If programmed no Handshake is required.
Pager Extend
(Pager Format Selected)
Pager PIN Number
-
Program if a PIN
number is required by the paging system.
The digits in Telephone Number 2 will be
added on to telephone number 1 and/or
telephone number 3 allowing for a total of 24
digits. See sample program below. Note: If
selected do not program backup reporting.
If a 7-digit PIN number is required, program
the panel as follows:
[31] - Pager Telephone number
[32] - Select Pager Format
[33] - Select Pager Extend
[41] -
D D D X X X X X X X C 0
[34]Zone Report, Telco 1
Select zone(s) required to send an alarm
report to Telephone Number 1.
[35]Zone Restore Report, Telco 1
Select zone(s) required to send a restore
report to Telephone Number 1. The zones
will send a restore after Bell time-out, unless
programmed as silent zones.
[36]System Reporting, Telco 1
(1) Keypad Panic 2
- Program to activate a
Keypad Panic 2 report (
KK
).
(2) AUX/AMBUSH
- Program to activate an
AUX or AMBUSH report (
ff
).
(3) Panic - Program to activate a Panic
report (
gG
).
(4) Test Timer - Program to activate a Test
Timer report.
PIN Number
Terminating Digit (#)
Delay
Leading 0
Pager display will appear as shown in Figure 7
except there will be only one leading 0.
000 033-1234
Leading Digits
Report Code
Subscriber ID Number
FIGURE
7 D
EFAULT
P
AGER
D
ISPLAY