Mitsubishi Electronics Q172CPU(N) Home Security System User Manual


 
7 - 80
7 OPERATION CONTROL PROGRAMS
F/FS G
7.13.5 Same data block transfer : FMOV
Refer to the Section "1.3.4" for the correspondence version of the Motion CPU and the
software.
Format FMOV(D), (S), (n) Number of basic steps 6
[Usable data]
Usable Data
Word device Constant
Setting
data
Bit device
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
Coasting
timer
16-bit
integer
type (K/H)
32-bit
integer type
(K/H, L)
64-bit
floating
point
type (K)
Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
(D)
— — — —
— — — —
(S)
— — —
— — — — —
(n) —
— — —
— — — — —
: Usable
[Setting data]
Setting data Description Data type of result
(D) Transfer destination device starting No.
(S)
Device No. which transfer data or data to be
transferred are stored.
(n) Number of words to be transferred
[Functions]
(1) The data specified with (S) or contents of word device are transferred a part for
(n)words of data to the word device specified with (D).
(2) The word devices that may be set at (D), (S) and (n) are shown below.
Word devices
(Note-1)
Bit devices
(Note-1), (Note-2)
Setting data
Dn Wn #n Mn Bn Fn Xn Yn
(D)
(Note-4)
(Note-3)
(Note-3)
(S)
(Note-3)
(Note-3)
(n)
— — — — —
(Note-1) : The device No. cannot be specified indirectly.
(Note-2) : Specify a multiple of 16 as the device number of bit data.
(Note-3) : PX/PY cannot be set.
(Note-4) : Special relays (M9000 to M9255) and dedicated devices (M2000 to M2399) cannot be set.