PEFY-2
PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E (June 2010)
PEFY-P-NMSU-E
PEFY-P-NMAU-E
PEFY-P-NMHU-E
CEILING-CONCEALED (LOW/MEDIUM/HIGH-STATIC PRESSURE)
PEFY-P-NMSU-E (Low Profile)
PEFY-P-NMHU-E
PEFY-P-NMSU-E
For PEFY-P-NMHU-E,
can be done from the side
all the maintenance work
inspection hole.
Low airflow Middle airflow High airflow
PEFY-P06NMSU-E 22 dBA 24 dBA 28 dBA
PEFY-P08NMSU-E 23 dBA 26 dBA 30 dBA
PEFY-P12NMSU-E 23 dBA 28 dBA 35 dBA
PEFY-P06,08,12,15,18,24NMSU-E Model
unit: mm(in.)
Long room
L-shaped rooms
Room with fixed
ceiling fixtures
PEFY-P15NMSU-E 28 dBA 30 dBA 33 dBA
PEFY-P18NMSU-E 30 dBA 34 dBA 37 dBA
PEFY-P24NMSU-E 30 dBA 35 dBA 40 dBA
The PEFY models are high-performance, ceiling-concealed indoor units. In fact, if it weren’t for the constantly comfortable environment these units deliver, you
would not know they were there. The ducted fan coils are designed to be installed above the ceiling, hidden from public view, and they’re extremely quiet with
lowest sound of 22 dBA. The PEFY are extremely easy to access and maintain according to their application. They open on one side so you can easily access
the fan or motor for maintenance. They can be easily customized to your cooling and heating needs. The external static pressure settings are adjustable to
meet different application conditions such as the use of a high performance filter.
The additional external static pressure up to 0.8 in.WG
on PEFY-NMHU-E provides flexibility for duct extension,
branching, and air outlet configuration.
7-7/8" extremely thin body of PEFY-NMSU-E requires less ceiling space
Access door
Ceiling surface
Service space (viewed from the side)
600 mm [23-5/8 in] or more
100 mm
[3-15/16 in]
or more
10 mm
[13/32 in]
or more
200 [7-7/8]
Flexible design allows for elegant interior layout
PEFY-P-NMAU-E (Medium Static)
PEFY-P-NMHU-E (Alt. High Static)
PEFY-P-NMAU-E
PEFY-P-NMSU has a condensate lift of 21-11/16 in.,
and PEFY-P-NMAU has a condensate lift of 27-9/16 in.
PEFY-P-NMSU-E
PEFY-P-NMHU-E
P08 P12 P15 P18 P30 P36 P48P06 P24 P27 P54 P72 P96
Ceiling concealed
48,000
6,700
Nominal cooling cap.*1
Nominal heating cap.*2
6,000 8,000 12,000 15,000 18,000 24,000 27,000 30,000 36,000 54,000 72,000 96,000
60,000 80,000 108,00027,000 30,000 34,000 40,000 54,0009,000 13,500 17,000 20,000
BTU/h
BTU/h
* (Details are referred to in the specification sheet.)
* Refer to the Nominal conditions *1, *2 in the Specification sheet.
* Refer to the Nominal conditions *1, *2 in the Specification sheet.
PEFY-P-NMAU-E
Sound Pressure Levels