PEFY-8
PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E (June 2010)
PEFY-P-NMSU-E
PEFY-P-NMAU-E
PEFY-P-NMHU-E
ModelPEFY-P15NMHU-EPEFY-P18NMHU-E PEFY-P24NMHU-E PEFY-P27NMHU-E
Power source 1-phase 208/230 V 60Hz
Cooling capacity BTU / h 15,000 18,000 24,000 27,000
(Nominal)
kW 4.45.3
7.
07
.9
Power input kW 0.188/0.207 0.188/0.207 0.245/0.270 0.270/0.297
*3
Current inpu
tA
0.96/1.060.96/1.061.25/1.3
81
.37/1.51
Heating capacity *2 BTU / h
17,000 20,000 27,000 30,000
(Nominal) kW 5.05.9 7.
98
.8
Power input kW
0.188/0.207 0.188/0.207 0.245/0.270 0.270/0.297
Current inputA
0.96/1.060.96/1.061.25/1.3
81
.37/1.51
External finish Galvanized
External dimension H x W x Din. 14-31/32 x 29-17/32 x 35-7/1614-31/32 x 29-17/32 x 35-7/1614-31/32 x 29-17/32 x 35-7/1614-31/32 x 39-3/8 x 35-7/16
mm 380 x 750 x 900380 x 750 x 900380 x 750 x 900380 x 1,000 x 900
Net weight lbs (kg) 98 (44) 100 (45) 100 (45) 111 (50)
Heat exchanger Cross fin(Aluminium fin and copper tube)
FANType x Quantity Sirocco fan x 1Sirocco fan x 1Sirocco fan x 1Sirocco fan x 1
External-
static
pressure
(208V)in.WG
(0.201*)-0.642 (208V)
Pa
(230V) in.WG
Pa
Motor type 1-phase induction motor
Motor output kW 0.130 0.1300.180 0.220
Driving mechanism Direct-driven
Airflow rate cfm353-494 353-494477-671 547-777
(Low-High) m3 / min10.0-14.0 10.0-14.013.5-19.0 15.5-22.0
L / s167-233 167-233225-317 258-367
Sound pressure level (Low-High) dB <A>25-32 (208V) 25-32 (208V) 29-36 (208V) 30-38 (208V)
(measured in anechoic room) dB <A>34-39 (230V) 34-39 (230V) 36-41 (230V) 35-41 (230V)
*3
dB <A> ----
Insulation material Polystyrene foam,Polyethylene foam,Urethane foam
Air filter Field-supplied; see Optional Parts
Protection device Fuse
Refrigerant control device LEV
Connectable outdoor unit R410A,R22 CITY MULTI
Diameter of Liquid(R410A)
in. (mm)
1/4 (6.35) Flare 1/4 (6.35) Flare3/8 (9.52) Flare3/8 (9.52) Flare
refrigerant pipe (R22 )1/4 (6.35) Flare 3/8 (9.52) Flare3/8 (9.52) Flare3/8 (9.52) Flare
(O.D.) Gas (R410A)
in. (mm)
1/2 (12.7) Flare 1/2 (12.7) Flare5/8 (15.88) Flare5/8 (15.88) Flare
(R22 )1/2 (12.7) Flare 5/8 (15.88) Flare 5/8 (15.88) Flare 5/8 (15.88) Flare
Field drain pipe size in. (mm) O.D. 1-1/4 (32) O.D. 1-1/4 (32) O.D. 1-1/4 (32) O.D. 1-1/4 (32)
DrawingExternal W277664
Wiring W660134
Refrigerant cycle -
Standard Document Installation Manual,Installation Book
attachment Accessory Drain hose I.D. 1-1/4inch (32mm)(flexible joint)
Optional partsDrain pump PAC-KE04DM-F PAC-KE04DM-F PAC-KE04DM-F PAC-KE04DM-F
External heater adaptor CN24RELAY-KIT-CM3
Filter box PAC-KE63TB-F PAC-KE63TB-F PAC-KE63TB-F PAC-KE80TB-F
Long life filter PAC-KE86LAF PAC-KE86LAF PAC-KE86LAF PAC-KE88LAF
Remarks *Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the
Installation Manual.
*Due to continuing improvement, above specification may be subject to change without notice.
*1
(0.201*)-0.642 (208V)(0.201*)-0.642 (208V)(0.201*)-0.642 (208V)
(50*)-160 (50*)-160
(50*)-160 (50*)-160
100-(150*)-200
100-(150*)-200 100-(150*)-200
100-(150*)-200
0.401-(0.602*)-0.803 (230V)
0.401-(0.602*)-0.803 (230V)
0.401-(0.602*)-0.803 (230V)
0.401-(0.602*)-0.803 (230V)
CN24RELAY-KIT-CM3
CN24RELAY-KIT-CM3
CN24RELAY-KIT-CM3
MCA
1.20 / 1.331.20 / 1.331.57 / 1.731.72 / 1.89
A
Ventilation Air: Providing sufcient ventilation air is an important part of every building design.
ASHRAE standard 62 provides the minimum ventilation air requirements. Also check local codes.
1. SPECIFICATIONS
Note: *1 Nominal cooling conditions *2 Nominal heating conditions Unit converter
Indoor:
80degF D.B. / 67degF W.B.
(26.7degC D.B. / 19.4degC W.B.)
70degF D.B. (21.1degC D.B.)
kcal/h = kW x 860
BTU/h = kW x 3,412
Outdoor: 95degF D.B. (35degC D.B.)
47degF D.B. / 43degF W.B.
(8.3degC D.B. / 6.1degC W.B.)
cfm = m3/min x 35.31
lbs = kg / 0.4536
Pipe length: 25 ft. (7.6 m) 25 ft. (7.6 m)
*Above specication data is
subject to rounding variation.
Level difference: 0 ft. (0 m) 0 ft. (0 m)
*3 The rated external static pressure is set to 50 Pa (0.20 in. WG) for 208V and 150 Pa (0.60) for 230V at factory shipment.
*Due to continuing improvement, above specication may be subject to change without notice.