Mitsubishi Electronics PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E Indoor Furnishings User Manual


 
PEFY-12
PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E (June 2010)
PEFY-P-NMSU-E
PEFY-P-NMAU-E
PEFY-P-NMHU-E
mm(in.)
(35-7/16)
(27-9/16)
(19-11/16)
(41-3/4)
(33-7/8)
(26)
(47-1/4)
(39-3/8)
(31-1/2)
(39-3/8)
(31-1/2)
(23-5/8)
(41-3/4)
(33-7/8)
(26)
(47-3/16)
(39-5/16)
(31-7/16)
(45-3/8)
(37-1/2)
(29-5/8)
(43-5/16)
(35-7/16)
(27-9/16)
700
Drain pipe(O.D.ø32(1-1/4))
(Emergency draining)
*2
*1
ø6.35(1/4)ø12.7(1/2)
PEFY-P18NMSU-E
900 952 998
860
9
800 1000 860
7
700
20
24
16
L
900
500
(48-25/32)
(40-29/32)
(33-1/16)
1039
1239
839
(46-7/8)
(39)
(31-1/8)
990
1190
790
KMN
9
5
J
1060
660
H
800600
7
660798752
Knockout hole ø27(1-3/32)
(Transmission wiring)
Knockout hole ø27(1-3/32)
(Power source wiring)
G
1200
F
1000
E
11
D
1060
C
1100
B
1152
PEFY-P06,08,12NMSU-E
PEFY-P15NMSU-E
PEFY-P24NMSU-E
Model A
1198
Gas pipe Liquid pipe
*1
*2
ø12.7(1/2)
ø15.88(5/8)
ø6.35(1/4)
ø9.52(3/8)
ø9.52(3/8)
ø15.88(5/8)
L-ø2.9(1/8)
2x2-ø2.9(1/8)
2xE-ø2.9(1/8)
Control box
Air filter
Suspension bolt hole
4-14x30(9/16x1-3/16) Slot
Terminal bed(Power source)
Refrigerant piping
brazing connection (liquid)
2
Refrigerant piping
brazing connection (gas)
1
Drain pipe(O.D.ø32(1-1/4))
(Gravity draining)
Terminal bed(Transmission)
Drain pump
Drain pipe(O.D.ø32(1-1/4))
Air
inlet
Air
outlet
(1-31/32~5-29/32)
159(6-9/32)
345(13-19/32)
(21-21/32)
(11-13/16)
(30-19/32)
(17-23/32)
(11-13/16)
(17-23/32)
More than 300
(13/16)
(13/32)
(3-9/16)
(5-29/32)
(2-25/32)(4-19/32)
70
10(13/32)
(3-15/16)
(1-15/16) (24-5/8)
450
37(1-15/32)
200(7-7/8)
H20(13/16)
157.5 (6-7/32)20(13/16)
100(3-15/16)
37(1-15/32)
12(1/2)
12(1/2)
88(3-15/32)
100(3-15/16)xJ=K
100(3-15/16)
88(3-15/32)
777
50(1-31/32)
50~150
50(1-31/32)
G
450
Less than 550
Less than 300
175
±5(6-29/32±7/32)
10(13/32)
49
25(1)
More than 20
More than 10
170(6-23/32)
102(4-1/32)
48(1-29/32)
270(10-21/32)
116
150(Duct)
23(29/32)
100 25(1)
700(27-9/16)
677(26-21/32)23(29/32)
C
M
B (Suspension bolt pitch)23(29/32)
A
N
90
625(Suspension bolt pitch)
100(3-15/16)
57(2-1/4)
D (Duct)
30(1-3/16) 100(3-15/16)x(E-1)=F
100(3-15/16)
20(13/16)
15(19/32)
<accessory>
Drain hose (I.D.ø32(1-1/4))
(Actual length)
Note2
Access door
Required space for service and maintenance
Access door
Ceiling surface
Make the access door at the appointed
position properly for service maintenance.
Note 1. Use M10 screw for the Suspension bolt (field supply).
2. Keep the service space for the maintenance at the bottom.
3. This chart indicates for PEFY-P15·18NMSU-E models,which has
3 fans.
PEFY-P06~12NMSU-E models have 2 fans.
PEFY-P24NMSU-E model have 4 fans.
4. In case of the inlet duct is used,remove the air filter(supply with
the unit), then install the filter(field supply) at suction side.
*1:R410A outdoor unit
*2:R22 outdoor unit
12
PEFY-P06,08,12,15,18,24NMSU-E
Ref.: PEFY_NMSU_EXD_USDB_ALL
Unit : mm(in)
2. EXTERNAL DIMENSIONS