Mitsubishi Electronics PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E Indoor Furnishings User Manual


 
PEFY-15PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E (June 2010)
PEFY-P-NMSU-E
PEFY-P-NMAU-E
PEFY-P-NMHU-E
2. EXTERNAL DIMENSIONS
DATA U3
PEFY-P-NMLU-E/PEFY-P-NMHU-E IU - A - 8
mm(in.)
4-14X30(9/16X1-3/16) Slot
Keep duct-work length 850mm(33-15/32 in.) or more.
Air inlet
Air outlet
Model:P15~30(Note3)
When installing the drain pump kit (option).
(19/32)
(1-31/32)
(1-31/32X4=7-7/8)
(2-3/8)
(6-13/32)
(13/32)
(1-
5/8)
(3-1/16)
(5-1/8)
(3-5/8)
(2-31/32)
(3-5/32)
(1-31/32)
(5-29/32~7-7/8)
(27-9/16)
(1-31/32)
(24-5/8)
(1-31/32)
(17-23/32)
(17-23/32)
(3-15/16~7-7/8)
3
780
(30-23/32)
450
(17-23/32)
10
500
(19-11/16)
11
50
(1-31/32)
550
(21-21/32)
600
(23-5/8)
680
(26-25/32)
754
(29-11/16)
800
(31-1/2)
1030
(40-9/16)
700
(27-9/16)
15
800
(31-1/2)
17
25
(1)
1230
(48-7/16)
900
(35-7/16)
19
1000
(39-3/8)
21
25
(1)
800
(31-1/2)
1000
(39-3/8)
1050
(41-11/32)
850
(33-1/2)
930
(36-5/8)
1004
(39-17/32)
1050
(41-11/32)
1130
(44-1/2)
1204
(47-13/32)
1250
(49-7/32)
( )
( )
LKJ HGFEDCBA
PEFY-P24NMHU-E
PEFY-P27
·
30NMHU-E
Model
PEFY-P36
·
48
·
54NMHU-E
PEFY-P18NMHU-E
5.On Model :18,36,48,54, you would use flare nut packed with the
Indoor Unit, when connecting the Outdoor Unit for R22.
Ceiling surface
Access door
Make the access door at the appointed position properly for service maintenance.
450
100~200
450
Required space for service and maintenance.
Note2
625
Access door
L
50
50
700
150~200
PEFY-P15NMHU-E
Suspension bolt hole
Terminal box
Drain hole
Control box
Drain hole
(option)
Drain hose
I.D.32mm (1-1/4inch)
<flexible joint>
(accessory)
Note1.Use M10 screw for the Suspension bolt (field supply).
2.Keep the service space for the maintenance from the bottom
when the heat exchanger is cleaned.
3.This chart indicates for PEFY-P36
·
48
·
54NMHU-E models, which has 2 fans.
PEFY-P15
·
18
·
24
·
27
·
30NMHU-E models have 1 fan.
4.Make sure to install the air filter(field supply) on the air intake side.
In case field supplied air filter is used, attach it where the filter
service is easily done.
Terminal bed
(Power source)
Terminal bed
(Transmission)
C
50X4=200
94(3-23/32)
163
(1-31/32)X5=(9-27/32)
300(11-13/16) or less
92 200(7-7/8)
343(13-17/32)
387(15-1/4)
77130
41
328(12-15/16)
25(1)
250(9-27/32)
50
380(14-31/32)
29(1-5/32)
15(19/32)
847(33-3/8)
900(35-7/16)
17(11/16) 340(13-13/32)
10(13/32)
45(1-25/32)
50X5=250
50(1-31/32)
50(1-31/32)X(G-1)=H
24(31/32)
550(21-21/32) Max
50(1-31/32)
20(13/16) or more
75
60
20(13/16) or more
E
250(9-27/32)
50(1-31/32)X(J-1)=K50
F
10
50(1-31/32)
80
15
23(29/32)
60(2-3/8)
383(15-3/32)
904(35-19/32)
A
B(Suspension bolt pitch)
814(32-1/16)(Suspension bolt pitch)
D
340(13-13/32)
30(1-3/16)
41
(1-5/8)
70
(2-25/32)
PEFY-P15,18,24,27,30,36,48,54NMHU-E
Drw. : IU-W277664
Unit : mm(in)
2. EXTERNAL DIMENSIONS