Mitsubishi Electronics PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E Indoor Furnishings User Manual


 
PEFY-4
PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E (June 2010)
PEFY-P-NMSU-E
PEFY-P-NMAU-E
PEFY-P-NMHU-E
Model PEFY-P18NMSU-E PEFY-P24NMSU-E
Power source 1-phase 208/230V 60Hz
Cooling capacity *1
(Nominal)
Btu / h 18,000 24,000
kW 5.3 7.0
Power input kW 0.09/0.09 0.12/0.12
Current input A 0.74/0.70 0.98/0.93
Heating capacity *2
(Nominal)
Btu / h 20,000 27,000
kW 5.9 7.9
Power input kW 0.07/0.07 0.10/0.10
Current input A
0.64/0.60 0.88/0.83
MCA A 1.20 / 1.33 1.57 / 1.73
External nish Galvanized
External dimension H x W x D
in. 7-7/8 x 39 x 27-9/16 7-7/8 x 46-7/8 x 27-9/16
mm 200 x 990 x 700 200 x 1190 x 700
Net weight Lbs (kg) 54(24) 62(28)
Heat exchanger Cross n(Aluminium n and copper tube)
Fan *3
Type x quantity Sirocco fan x 3 Sirocco fan x 4
External
Static pressure
in.WG 0.02-(0.06*)-0.14-0.20 (208V) 0.02-(0.06*)-0.14-0.20(208V)
PA 5-(15*)-35-50 5-(15*)-35-50
in.WG 0.02-(0.06*)-0.14-0.20 (230V) 0.02-(0.06*)-0.14-0.20(230V)
PA 5-(15*)-35-50 5-(15*)-35-50
Motor type DC brushless motor
Motor output kW 0.096 0.096
Driving mechanism Direct-driven
Airow rate
(Low-Mid-High)
cfm 353-441-529 423-565-706
m
3
/ min. 10-12.5-15 12-16-20
L / s 167-208-250 200-267-333
Sound pressure level (Low-Mid-High)
(Measured in anechoic room) *3
dB <A> 30-34-37 (208V) 30-35-40 (208V)
dB<A> 30-34-37 (230V) 30-35-40 (230V)
dB <A> - -
Insulation material Polystyrene foam,Polyethylene foam,Urethane foam
Air lter PP Honeycomb fabric (washable)
Protection Device Fuse
Refrigerant Control Device LEV
Connectable Outdoor Unit R410A,R22 CITY MULTI R410A,R22 CITY MULTI
Diameter of
refrigerant pipe
(O.D.)
Liquid (R410A)
(R22 )
in. (mm)
1/4 (6.35) Brazed 3/8 (9.52) Brazed
3/8 (9.52) Brazed 3/8 (9.52) Brazed
Gas
(R410A)
(R22 )
in. (mm)
1/2 (12.7) Brazed 5/8 (15.88) Brazed
5/8 (15.88) Brazed 5/8 (15.88) Brazed
Diameter of drain pipe in. (mm) O.D. 1-1/4(32) O.D. 1-1/4(32)
Drain lift mechanism in. (mm) 21-11/16 (551) 21-11/16 (551)
Drawing
External WKB94L522
Wiring WKB94L523
Refrigerant cycle -
Standard
Attachment
Document Installation Manual, Instruction Book
Accessory Drain hose (exible joint)
Optional Parts External heater adaptor CN24RELAY-KIT-CM CN24RELAY-KIT-CM
Remark Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other
items shall be referred to the Installation Manual.
1. SPECIFICATIONS
Note: *1 Nominal cooling conditions *2 Nominal heating conditions Unit converter
Indoor:
80degF D.B. / 67degF W.B.
(26.7degC D.B. / 19.4degC W.B.)
70degF D.B. (21.1degC D.B.)
kcal/h = kW x 860
BTU/h = kW x 3,412
Outdoor: 95degF D.B. (35degC D.B.)
47degF D.B. / 43degF W.B.
(8.3degC D.B. / 6.1degC W.B.)
cfm = m3/min x 35.31
lbs = kg / 0.4536
Pipe length: 25 ft. (7.6 m) 25 ft. (7.6 m)
*Above specication data is
subject to rounding variation.
Level difference: 0 ft. (0 m) 0 ft. (0 m)
*3 The external static pressure is set to 15 Pa (0.06 in. WG) at factory shipment.
*Due to continuing improvement, above specication may be subject to change without notice.
Ventilation Air: Providing sufcient ventilation air is an important part of every building design.
ASHRAE standard 62 provides the minimum ventilation air requirements. Also check local
codes.