Mitsubishi Electronics MS24WN Air Conditioner User Manual


 
32
Check of indoor electronic control P.C. board
C
The unit doesn’t operate with the remote controller.
Also, the OPERATION INDICATOR lamp doesn’t light up by pressing the EMERGENCY OPERATION switch.
Check the both “parts side”and “pattern side” of
indoor electronic control P.C. board visually.
Replace the fuse.
Is fuse(F11) blown?
Be sure to check both fuse
and varistor in any case.
Replace the fan
motor.
Replace the
indoor electronic
control P.C. board.
Is winding
resistance of
fan motor 0 "?
Is winding
resistance of
vane motor 0 "?
No
Yes
Replace the vane
motor.
Turn OFF the
power supply.
Turn OFF the
power supply.
No
Yes
Yes
Is varistor(NR11) burnt?
Replace the varistor.
Yes
Turn OFF the power supply.
Remove indoor fan motor connector CN211 and vane
motor connector CN151 from the indoor electronic
control P.C. board and turn ON the power supply.
No
No
Does the unit operate with the remote controller?
Does the OPERATION INDICATORE lamp light up
by pressing the EMERGENCY OPERATION switch?
No
Yes
Be sure to check both resistance.
Varistor (NR11)
Indoor electronic
control P.C. board
Fuse (F11)
OB311--2.qxp 04.1.13 10:01 AM Page 32