19
E
Item
Model
W
Cooling*2 capacity
BTU/h
Total input kW
W
Heating*3 capacity
BTU/h
Total input kW
Model name
Power supply*1
Air flow (Lo-Hi) CMM
Fan Noise level (Lo-Hi) dB (A)
Motor output kW
Booster heater kW
Dimensions (H × W × D) mm
Weight kg
Dimensions (H × W × D) mm
Weight kg
Model name
Power supply*1
Fan
Air flow CMM
Motor output kW
Compressor motor output kW
Crankcase heater W
Dimensions (H × W × D) mm
Weight kg
Noise level dB (A)
Performance *4
Indoor unit
Grille
Outdoor unit
Notes: *1 Refer to the product nameplate attached to the unit for the electrical specifications.
*2 Rating conditions (cooling) Indoor : 27°C DB, 19°C WB Outdoor : 35°C DB
*3 Rating conditions (heating) Indoor : 21°C DB Outdoor : 7°C DB, 6°C WB
*4 These data based on indicated voltage. 1ph, 240V
*5 Specifications subject to change without notice.
Operating range
Indoor air intake temperature Outdoor air intake temperature
Cooling
Maximum 35°C DB, 22.5°C WB 46°C DB
Minimum 21°C DB, 15.5°C WB –5°C DB
Heating
Maximum 27°C DB 21°C DB, 15.5°C WB
Minimum 20°C DB –8.5°C DB, –9.5°C WB
Units should be installed by licensed electric contractor accordingly to local code requirement.
PLH-2KKC
5350
18300
2.32
6000
20500
2.29
PLH-2KKC
~ (1ph), 240V, 50Hz
13 - 16
32 - 37
0.030
–
253 × 660 × 660
19
30 × 760 × 760
3.7
PUH-2AKA
~ (1ph)
240V
50Hz
45
0.065
1.7
38
650 × 870 × 295
64
49
PLH-2.5KKC
6200
21200
2.54
6900
23500
2.30
PLH-2.5KKC
~ (1ph), 240V, 50Hz
14 - 17
35 - 39.5
0.030
–
253 × 660 × 660
20
30 × 760 × 760
3.7
PUH-2.5AKA
~ (1ph)
240V
50Hz
50
0.085
2.0
38
850 × 870 × 295
68
52
8. Specifications