Honeywell HM506 Humidifier User Manual


 
Installation Guide
69-2285EFS—03 16
M28710
2. Whentankisempty,
turn the manual
shut-off valve at the
bottom of the tank to
“Unlock”.
3. Grip the white water
valve arm and push
it back to disengage
from the tank’s black
spool.
4. Firmly grip the tank
bottom. Push down
the cover's safety
button and pull the
latch forward to
release the tank.
Note: Latch does not
come off humidifier with
tank.
M24777
M24778
M24779
5. Use tap water to flush loose minerals from
the tank. Sediment screen at tank's bottom
isremovable.Foramorethoroughcleaning,
soaktankinwarm,soapywater,thenrinse
clean. Tank is also dishwasher-safe.
Note: Do not use hydrocarbon oil-based
cleaners.
6. Carefully rub minerals off of the
heating element and tank walls.
Clear sensor compartment holes of
debris if present.
M24856
M24857
Sediment screen
7. Remove TrueSTEAM cover. Inspect
water level sensor. If debris build-
upispresent,replace.
MAINTENANCE
Remove T-30 Torx
screw and lift clamp.
Ensure sensor gaskets are seated properly and
are in good condition (no cracks).
Remove
Caution
For steps 6–7, unplug TrueSTEAM.