Honeywell 4500 Thermostat User Manual


 
4500 Thermostat Installation Instructions
4-8
For Fields 13-15, select the 3-digit word codes from Table 5 for each descriptor.
If you want less than a 3-word description for the thermostat, set unused
descriptors to 0 0 0.
Note: Fields 13 thru 15 select a voice announcement to be associated with
thermostat #2.
For example, if you wanted a voice announcement for “central hall
temperature,” you would program Field 13 as 089; Field 14 as 050; and Field
15 as 158.
If you only wanted a voice announcement for “hall temperature” you would
program Field 13 as 000; Field 14 as 050; and Field 15 as 158.
Field 13: Thermostat #2 Descriptor #1
Default value: 0 0 0 = no announcement [default]
Field 14: Thermostat #2 Descriptor #2
Default value: 0 0 0 = no announcement [default]
Field 15: Thermostat #2 Descriptor #3
Default value: 0 0 0 = no announcement [default]
This completes the programming of the 4500. Once all necessary
fields have been programmed, hang up the phone.
If you want to reenter the 4286 Programming Mode after exiting, you will have
15 minutes to do so using the procedure beginning on page 4-2 of this manual.
The 15 minute time limit is to prevent the user from accidentally entering
programming mode. If more than 15 minutes have passed, you must reset the
system by removing the 12VDC power temporarily from the 4286 by
disconnecting the keyed header that connects it to the control panel (located
near the 2 relays). Wait at least 5 seconds, then reconnect the keyed header
and follow the procedure To Enter and Use the 4286 Programming Mode on
page 4-2 of this manual.