Hobart HC24EO3 HC24EO5 Carpet Cleaner User Manual


 
— 17 —
HC24EO SERIES STEAMER
Developed by Packer Engineering, Naperville, Ill., an independent testing laboratory.
MAINTENANCE
: The steamer and its
parts are hot. Use care when operating,
cleaning or servicing the steamer. The
cooking compartment contains live steam
and hot water. Stay clear when opening
the door.
Steamer must be cleaned daily. See CLEANING
section.
REMOVAL OF LIME SCALE DEPOSITS
: Read and follow the
instructions on the deliming material
package. Avoid contact with skin and eyes.
Wear plastic or rubber gloves and safety
goggles when handling. Wash thoroughly
after handling. If deliming solution comes
in contact with the skin or eyes, rinse
thoroughly with clean water.
: The steamer and its
parts are hot. Use care when operating,
cleaning or servicing the steamer. The
cooking compartment contains live steam
and hot water. Stay clear when opening
the door.
The steamer should be delimed when scale
is present in the cavity well. Deliming may be
required frequently depending on water quality
and scale build up. This is in accordance with
the minimum preventive maintenance schedule
required by warranty.
Items required (not provided):
1. Deliming Solution – Scale Release™
Part Number 854893-13 (qty. 1).
Contact the local Authorized Vulcan
Servicer or refer to website
www.hobartcorp.com
2. Plastic or rubber gloves.
3. Safety goggles or face shield.
4. Spray bottle.
5. 1-gallon container for mixing the deliming
solution.
NOTE: Deliming solution may cause the surface
of aluminum measuring tools to tarnish
or etch.
Procedure:
1. Turn steamer off. Drain the steamer.
2. One bag will treat a C24EO3 or C24EO5
steamer.
1 bag to 2 gallons warm water
3. Spray cavity walls with solution. Pour
solution into cavity well.
Maximum steamer capacity 3 gallons
4. Fully depress Power Switch to ON
position and set Timer for 5 min. After timer
sounds, rotate Timer dial to OFF position
and fully depress Power Switch to OFF
position.
5. Let delime solution soak for a minimum of
30 minutes, maximum 60 minutes. If scale
is still present, repeat steps 1 through 5.
6. Drain the steamer and rinse thoroughly with
warm clean water.
7. Dry with a clean dry cloth.
8. Leave steamer door open when not in use.
DOOR GASKET
If the door gasket is leaking due to a nick or
cut, it must be replaced. Damage to the gasket
sealing surface will cause steam leakage.