Heat & Glo LifeStyle RED40 Indoor Fireplace User Manual


 
Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12
57
Figure 13.10 Noncombustible Surface Finishing Material 0-4 Inches Thick-Inside Fit Method
The mesh decorative front is approved for inside t ap-
plications. Non-combustible nishing materials up to 4
inches thick can be installed around the Mesh front (left,
right, top, and bottom). The inside t method requires an
additional 2 in. of 1/2 in. thick non-combustible building
material (not supplied with replace) to be installed on
the left and right sides ush with the factory installed non-
combustible board.
Figure 13.9 Inside Fit Method
Non-Combustible Finish Materials
0 Inches to 4 Inches Thick Inside Fit Method
1/2 IN. THICK
WALL SHEATHING
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
\\\
0-4 IN.
16-1/2 IN.
0- 4 IN.
DRYWALL OR
EQUIVALENT (1/2 IN.)
1/2 IN.
13-1/8 IN.
1/2 IN.
15-1/2 IN.
1-1/2 IN.
1-1/2 IN.
16-1/2 IN.
1-3/16 IN.
1-3/16 IN.
45-1/2 IN.
FIREPLACE VIEWING AREA
= CLEARANCE FROM VIEWING AREA TO NON-COMBUSTIBLE FINISHING MATERIAL
(INSIDE FIT METHOD)
13-1/8 IN.
42-3/4 IN.
Ensure that no non-combustible nish materials are in-
stalled within 1-1/2 inches of top and bottom and 1-3/16
inches from right and left sides of replace opening. This
will ensure adequate clearance for required mesh front.
See Figure 13.11.
Refer to Section 1.E and 1.F of this manual for de nition
and quali cations and de nition of non-combustible and
combustible materials.