Heat & Glo LifeStyle RED40 Indoor Fireplace User Manual


 
Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/1254
C. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as speci ed. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Note: For non-combustible replace nish material (marble,
stone, etc) speci cations refer to Figure 13.10 and Figure 13.11.
Combustible Mantels
Figure 13.4 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Combustible Mantel Legs Or Wall Projections
Extending Past The Face Of The Fireplace
UNLIMITED
6 IN.
MIN.
2 IN.
MIN.
FIREPLACE
OPENING
4 IN.
MAX.
= ACCEPTABLE
NON-COMBUSTIBLE
MANTEL LEG
ZONE
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
7
8
9
10
11
12
13
31
TO CEILING
9
10
11
12
8
7
6
25
18
Note: For non-combustible replace nish material (marble,
stone, etc) speci cations refer to Section 13.
Note: All
measurements
in inches.
Non-Combustible Mantels
MEASUREMENTS FROM TOP EDGE OF THE
FIRESCREEN DOOR ASSEMBLY
8
9
10
16
7
6
5
4
1
2
3
4
5
6
12
31
MAX.
MIN.
TO CEILING
1/2
Note: All
measurements
in inches.
Figure 13.2 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
Figure 13.3 Minimum Vertical and Maximum Horizontal
Dimensions of Non-Combustibles