Heat & Glo LifeStyle RED40 Indoor Fireplace User Manual


 
Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12
25
Figure 7.4
Top Vent - Horizontal Termination
Venting with 1 elbow
H
1
V
1
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling restops.
ALWAYS maintain speci ed clearances around venting and restop systems.
Install wall shield and ceiling restops as speci ed.
Failure to keep insulation or other material away from vent pipe may cause re.
WARNING
Note: Use DVP Series
components only.
V
1
Minimum H
1
Maximum
1 ft. 305 mm 2 ft. 610 mm
2 ft. 610 mm 6 ft. 1829
3 ft. 914 mm 9 ft. 2743
4 ft. 1219 mm 12 ft. 3658
5 ft. 1524 mm 15 ft. 4572
6 ft. 1829 mm 18 ft. 5486
7 ft. 2134 mm 21 ft. 6401
8 ft. 2438 mm 24 ft. 7315
V
1
+ H
1
= 63 ft. (19.2 m) Maximum
Note: 12 inches minimum vertical is
required prior to attaching any elbow
to the appliance.