Heat & Glo LifeStyle 6000XLS Indoor Fireplace User Manual


 
8
3
Installing the
Fireplace
Step 1
Locating the
Fireplace
The diagram below shows space and clearance
requirements for locating a fireplace within a room.
MODEL A B C D E
6000TR &
42 22 37 1/8 52 1/2 74 1/4
6000XLS
6000XLT-CDN 42 22 35 1/4 49 3/4 70 3/8
6000ARCH 42* 22 35 1/4 49 3/4 70 3/8
48 1/4
**
* SURROUND IN FRONT OF FINISHED WALL
** SURROUND FLUSH WITH FINISHED WALL.
NOTE: DIMENSIONS SHOWN IN INCHES.
Figure 3. Fireplace Dimensions, Locations, and
Space Requirements
Clearance Requirements
The top, back, and sides of the fireplace are defined
by stand-offs.
Minimum Clearances from the Fireplace to
Combustible Materials
Glass Rear of Sides of Top of
Front Floor Fireplace Fireplace Fireplace Ceiling
36 inches 0 1/2 inch 1/2 inch 3-1/2 inches 31 inches
(914 mm) (13 mm) (13 mm) (89 mm) (787 mm)
The minimum clearance to a perpendicular wall extend-
ing past the face of the fireplace is one inch (25 mm).
The back of the fireplace may be recessed 21 1/2
inches (546 mm) into combustible construction.