Heat & Glo LifeStyle 6000XLS Indoor Fireplace User Manual


 
41
This model is equipped with a baffle which will allow you
to control usable heat output. The baffle control lever is
located at the lower left corner of the unit behind the lower
grille. See Figure 39.
FOR MORE HEAT: Pull the baffle lever forward and down.
This will close the baffle.
FOR LESS HEAT: Push the baffle lever back and up to
lock. This will open the baffle.
FIGURE 39
After the
Installation
LEAVE THIS INSTALLATION MANUAL
WITH THE APPLIANCE FOR FUTURE
REFERENCE.
Step 13
Heating Control
Model 6000XLT-CDN
Step 14
Relief Ports
Model 6000ARCH
Model 6000 ARCH has a relief port built into the underside
of the firebox (behind the lower grille). See Figure 40. The
port cover plate is spring-loaded to remain closed. The
cover plate activates a safety microswitch which is wired
to the DSI control valve. See Figure 33 DSI Wiring Diagram.
In the unlikely event of a delayed lighting of the burner, the
relief cover plate is designed to open and release the
microswitch lever. This will prevent the DSI valve from op-
erating until the cover plate is re-set and the microswitch
lever closed. To Re-set: 1. Pull and hold the microswitch
lever arm DOWN. 2. Push the cover plate UP and release
the switch lever arm. See Figure 40.
FIGURE 40
!