Heat & Glo LifeStyle 6000XLS Indoor Fireplace User Manual


 
21
WARNING: ENSURE THAT THE FIBER-
GLASS ROPE GASKET SUPPLIED WITH
THE FIREPLACE SEALS BETWEEN THE
FIRST VENT COMPONENT & THE OUTER
FIREPLACE WRAP.
1. Attach the First Vent Component to the
Starting Collars
To attach the first vent component to the starting collars
of the fireplace:
Apply a 3/8 inch (9.5 mm) bead of stove cement
around the 5 inch (127 mm) fireplace starting collar.
Make sure that the fireplace rope gasket supplied with
the fireplace seals between the first 8-5/8 inch
(219 mm) vent component and the outer fireplace wrap.
Lock the vent components into place by sliding the
concentric pipe sections with four (4) equally spaced
interior beads into the fireplace collar or previously
installed component end with four (4) equally spaced
indented sections.
When the internal beads of each 8-5/8 inch
(219 mm) outer pipe line up, rotate the pipe section
clockwise about one-quarter (1/4) turn. The vent pipe
is now locked together.
The first 90° elbow installed in the vent system of a
rear venting fireplace MUST BE in a vertical position.
1. Apply the stove ce-
ment.
2. Line up the internal
beads and rotate the
pipe sections clock-
wise until locked.
3. Lock the vent compo-
nents into place.
4. Check the seal on the
rope gasket.
Figure 16. Attaching the First Vent Component to
the Starting Collars
WARNING: A 3/8 INCH (9.5MM) BEAD OF
STOVE CEMENT MUST BE PLACED
AROUND THE 5 INCH (127MM) FIRE-
PLACE STARTING COLLAR BEFORE AT-
TACHING THE FIRST VENT COMPO-
NENT. FAILURE TO SEAL THIS JOINT
MAY CAUSE THE FIREPLACE TO OPERATE
IMPROPERLY. SEE THE ABOVE DIAGRAM .
!
!
STARTING
COLLAR
STOVE
SEALANT
BEAD
1 INCH (25.4mm)
FIRST VENT
COMPONENT