Haier ESA412K Air Conditioner User Manual


 
Short-circuit -ON-Ĝ Open-circuit -OFF-h
Function description Note
Bit0
Address code Ā1ā Address code “0ā
Central control indoor address Bit0/wired control indoor address Bit0
Bit1
Address code Ā1ā Address code Ā0ā
Central control indoor address Bit1/wired control indoor address Bit1
Bit2
Address code Ā1ā Address code Ā0ā
Central control indoor address Bit2/wired control indoor address Bit2
SW1-1
2
3
4
Bit3
Address code Ā1ā Address code Ā0ā
Central control indoor address Bit3/wired control indoor address Bit3
Bit4
Address code Ā1ā Address code Ā0ā
Central control indoor address Bit4
Bit5
Address code Ā1ā Address code Ā0ā
Central control indoor address Bit5
Bit6
Address code Ā1ā Address code Ā0ā
Central control indoor address Bit6
SW2-1
2
3
4
SLCT Control combination: AND
Control combination: the later
entering in priority
Control mode: remotr or wired control and passive port control
J1 Control type: remote control Control type: wired control Select control type, communication port and protocol selection
J2
Heating temp. compensation 4ć Heating temp. compensation 0ć
Select temp. compensation
J3 Control type: with outdoor PCB Control type: without outdoor PCB Select control type, control board
SW3-1
2
3
4
J4 Heat pump type Colling only type
1/60 1/60 In time shorting state Normal state
CHECK CHECK Use compulsory switch Normal state
J5 Ornarment or not
h/Ĝ
SW4-1
2
J6 Oxygen or not
h/Ĝ
J7 Other/2P convertible type
Ĝ/h
J8 Single split/multi split
Ĝ/h
J9 Indoor address 0 Setting indoor address by SW1 Select the address of wired control type multi indoor unit
SW5-1
2
3
4
J10 Fixed frequency Inverter
Central control indoor address: the indoor unit should be connected by the different uniquely address when select central control type, or will influence the control. For example, if
the address repeat, the control information will conflict or communication system will breakdowm. Central control address = dip switch value+1.
Wired control indoor address: the indoor unit should be connected by the different uniquely address when select wired control type, or will influence the control. For example, if
J9=ON, the wired controller can only indicate 1 indoor unit no matter how many indoor units its connected. Wired control address = dip switch value.
>a__WcU[S^ <[c >a`V[e[a`Wc
Functions and notes for dip switch (Ĝ shows ON, h shows OFF ) (for 0010451690E)