Haier ESA412K Air Conditioner User Manual


 
>a__WcU[S^ <[c >a`V[e[a`Wc
Jumper selection (Ĝshows jumper connected, ON; hshows jumper disconnected, OFF; * shows no limitation)
Time shorting switch CN7 Emergency switch SW1(receiver) BM1(1) BM1(2)
Time shorting switch Time shorting * * *
Emergency switch * Emergency * *
No outdoor PCB * *
hh
With outdoor PCB, fixed speed single split unit * *
Ĝh
With outdoor PCB, fixed speed multi split unit * *
With outdoor PCB, inverter single split unit * *
ĜĜ
Inverter unit selection BM2(1) BM2(2) BM2(3) BM2(4)
Temp. compensation 4ć available/not available Ĝ/h
* * *
Wired control/ infrared control *
Ĝ/h
* *
Cooling only/heatpump * *
Ĝ/h
*
Master/slave wired controller * * *
Ĝ/h
Network address selection (Ĝshows jumper connected, ON; hshows jumper disconnected, OFF)
BM4 BM3
address 1 2 3 4 1 2 3 4
1
h h h h h h h
2
Ĝ h h h h h h
3
h Ĝ h h h h h
4
Ĝ Ĝ h h h h h
hshows no network
home appliance
5
h h Ĝ h h h h
6
Ĝ h Ĝ h h h h
ĂĂ ĂĂ ĂĂ ĂĂ ĂĂ ĂĂ ĂĂ
126
Ĝ h Ĝ Ĝ Ĝ Ĝ Ĝ
127
h Ĝ Ĝ Ĝ Ĝ Ĝ Ĝ
128
Ĝ Ĝ Ĝ Ĝ Ĝ Ĝ Ĝ
Ĝwith network home
appliance
0010452325E / 0010452478E information - function selection
-152-