GTO UL325 SERIES Garage Door Opener User Manual


 
Setting Pull-to-Open (Closed) Gate Limit (for push-to-open go to pg. 27)
ON
1
3
2
1
2
Control Box Settings
SET
LIMIT
STATUS
ON
1 2 3 4 5 6 7
DIP
3
4
2
1
With gate in OPEN position, turn control box power ON.
Press button on opener remote; gate should start closing. Press button
on opener remote again when gate is in desired CLOSED position.
Press and hold the “SET LIMIT” button for 5 seconds. Press button on opener remote to fully open gate. Closed limit is
set upon reaching fully open position. Test and, if needed, reset
and start over.
26
2
5
1
Press and hold the “SET LIMIT” button for 10 seconds to clear.
Go back to the setting closed limit steps on the top of this page.
Press button on opener remote to open gate.
SET
LIMIT
STATUS
ON
1 2 3 4 5 6 7
DIP
6
Resetting Closed Gate Limit
NOTE: If your gate obstructs before it fully closes, you may
need to increase the stall force. (See page 28)