Goodman Mfg SS-CPC36-72 Air Conditioner User Manual


 
prodUCt speCifiCations
prodUCt speCifiCations
34 www.goodmanmfg.com SS-CPC36-72
wiring diagram — CpC036-72*4B/7B (460V/575V, Belt driVe)
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
Warning
High Voltage: Disconnect all power before servicing or installing this unit. Mulple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
H
1
PU
2
GR
3
BR
Y1
T
BL
3 6
/
4
RD
YL
6
0
WH
PU
LVJB
PLF2
5
GND
OR
PU
YL
YL
F
T
CONTROL
BR
T1
O
1
4
BR
BR
BK
9
RD
R
RCCF
3
C
W2
T
PLF1
BL
7
5
PU
T3
G
T2
R
WH
A
GR
CM
W1
RD
8
E
YL
M
2
BL
S
BOX
++
YL
COMP
C
Y/Y2
6
LPS
HPS
BL/PK
YL/PK
TB1
PU
OR
O
RD
GR
BK
NOTE#2
GR
C
RD
SEE
NOTE#2
BK
BL
T1
T2
M2
3
YL
BK
EBTDR
BL
YL/PK
M1
K1
L1
BK
PU
RD
BR
1
K1
24V
L2
BR
C
GR
TR
NO
NC
BL
RD
BK
T3
208
L3
2
0
8
-
2
4
0
-
4
6
0
-
5
7
5
RD
BL
COM
/
RD
RD
BK
BK
RD
PK
TB1
SMOKE/FIREDETECTOR
REPLACESJUMPER
S1
2
240
460
575
S2
RD
BL
G
XFMR-R
XFMR-C
BK
SPEED
C
UP
R
BL
RD
BL
OR
GR
T3
BK
BC
T1
RD
OR
C
EM
T2
L1
L2
L3
208-240-460-575/3/60 0140L00427 REV. B
SEENOTE#3
C
RCCF
EBTDR
C
L2
R
4
T3
T1
5
Y
Y2
COMP
N
OTES:
1. REPLACEMENTWIREMUSTBESAMESIZEAND
TYPEINSULATIONASORIGINAL(ATLEAST105°C)
USECOPPERCONDUCTORONLY.
2. USECOPPERCONDUCTORSONLY
++ USEN.E.C.CLASS2WIRE
3. ECONOMIZERPLUGLOCATEDINTHERETURNAIR
COMPARTMENT,REMOVE MALEPLUG,ATTACH
FEMALEPLUGTOTHEECONOMIZERACCESSORY.
4. FOR208VOLTTRANSFORMEROPERATIONMOVE
BLACKWIRESFROMTERMINAL 3 TOTERMINAL 2
ONTRANSFORMER.
T2
O
G
P
L
F
1
THERMOSTAT
3
6
F
208-240-460-575/3/60 0140L00427REV.B
Y1
R
COMPONENTLEGEND
G
SUPPLYVOLTAGE
CM
W2
EM
L1
W1
C
T1
6
BC
C
CM
CMR
COMP
DC
DFT
ECON
EBTD
EMR
R
EM
FC
GND
HPS
HVDR
LPS
LVDR
LVJB
PB
PLF
RVC
RCCF
TB1
TR
3
C
1
C
C
24V
PLF2
C
T3
L3
BLOWERCONTACTOR
CONTACTOR
CONDENSERMOTOR
CONDENSERMOTORRELAY
COMPRESSOR
DEFROSTCONTROL
DEFROSTTHERMOSTAT
ECONOMIZER
ELECTRONICBLOWERTIMEDELAY
EVAPORATORMOTORRELAY
RELAY
EVAPORATORMOTOR
FANCAPACITOR
EQUPIMENTGROUND
HIGHPRESSURESWITCH
HIGHVOLTAGEDEFROSTRELAY
LOWPRESSURESWITCH
LOWVOLTAGEDEFROSTRELAY
LOWVOLTAGEJUNCTIONBOX
POWERDISTRUBTIONBLOCK
FEMALEPLUG/CONNECTOR
REVERSINGVAVLECOIL
RUNCAPACITORFOR
COMPRESSORANDFAN
TERMINALBLOCK(24VSIGNAL)
TRANSFORMER
TR
4
OFOVERCURRENTPROTECTION
5
BC
SEEUNITRATINGPLATEFORTYPEANDSIZE
208-240V
208-240/3/60
T2
P
L
F
1
2
1
BC
EBTDR
R
EBTDR
HPS
LPS
BC
TB1
TB1
BC
++
LOWVOLTAGE
LINEVOLTAGE
FIELD
WIRING
LOWVOLTAGE
OPTIONAL
HIGHVOLTAGE
FACTORYWIRING
HIGHVOLTAGE
BL
RD
OR
Y1
Y/Y2
YL
W
Y/Y2
BL
G
R
OR
W
NOECONOMIZER
G
OR
YL
RD
Y/Y2
Y1
PK
WH
W
R
RD
WH
GR
C
O
R
YL
O
GR
Y1
G
WH
W
ITHECONOMIZEROPTION
C
GR
THERMOSTAT
FIELDWIRING
BL
C
O
2STAGECOOLING
TB1
G
R
W
Y
C
O
TB1
TB1
Y
W
O
R
G
C
W
Y2
G
R
C
O
Y1
STAT
STAT
STAT
BL/PK BLUEWITHPINKSTRIP
YL/PK YELLOWWITHPINKSTR IP
GR GREEN
W
IRECODE
BL BLUE
PU PURPLE
PK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW