GE 6100 Air Conditioner User Manual


 
6
Introduction
This manual is designed to provide product, performance
and application information to our customers and their
architects and engineers for use in selection and design
of a zonal comfort control system utilizing GE Zoneline
®
Packaged Terminal Air Conditioners (PTAC) and Packaged
Terminal Heat Pumps (PTHP). GE Zoneline PTACs and PTHPs
are self-contained units designed for through-the-wall
installations in hotels, motels, apartments, hospitals,
nursing homes, add-on rooms and many other installations.
Zoneline units provide individual room or zone control in both
cooling and heating operation. There is a model for practically
every application, ranging in cooling capacity from 7,200 to
14,800 BTUH and heating capacity from 6,400 to 14,000 BTUH
in heat pump operation. See pages 42 and 54 for resistance
heaters available.
Zoneline offers a two-tier lineup: The Deluxe Line consists of
the 4100 Series with electric resistance heat, the 4100 Series
Dry Air 25 Models with enhanced dehumidification for hot
and humid climates and the 6100 Series heat pump. The
6100 Series heat pump features reverse cycle defrost and
simultaneous supplemental resistance heat, when needed,
to maintain room comfort. Both offer tactile touch controls
with digital display and optional corrosion protection.
Deluxe Line Standard Features:
•Two-fan-motorsystemwithIndoorCross-Flow
Blower for quieter operation
•DigitalControls
—LED Temperature Display
—Easy Temperature Selection
—Tactile Touch Pad
•UniversalHeaters 
•HeatSentinel
• “L”CoilDesignCondenser
• 3-PositionVentDoor
• FreezeSentinel
•IndoorCoilFrostControl
•CentralDeskControlInterface
•RemoteThermostatControlInterface
•RandomRestart 
•ElectronicTemperatureLimiting
• “SmartFan”FanCycle/ContinuousControl
•TransferFanInterface
•ReverseCycleDefrostandSimultaneous
Supplemental Resistance Heat on Heat Pumps
• QuickHeatRecovery
Deluxe Line Optional Features:
• CorrosionProtection
•InternalCondensateRemoval(on6100Series
Heat Pump without Corrosion Protection)
NOTE: Dry Air 25 models include all the standard features of the
4100 Series plus standard corrosion protection.
Advantages of the GE Zoneline System:
• FlexibleApplication
— May be installed from flush to finished floor to
3" from the ceiling
— 7,200 to 14,800 BTUH units in same physical size
— Deluxe 4100 and 6100 Series may be ducted to
condition more than one room
— Compatible with Class 2 remote thermostat control
— Compatible with 2-wire CDC or many Energy
Management Systems
• EconomicalInstallation
— No ductwork necessary
— No mechanical equipment rooms or pipes required
for heating/cooling units
— Replacement units fit existing 42"-wide by 16"-high
wall cases
• QuietOperation
Indoor cross-flow blower
• Energy-SavingOperation
— Units in unoccupied areas may be turned off
Designed for efficient cooling operation — EERs from
10.6 to 13.2
— Efficient heat pump units — COPs from 3.3 to 4.0
Extended heat pump operation without sacrificing
room comfort
• EaseofMaintenance
Permanently lubricated fan motors
Upfront lift-out interchangeable filters
Slide-out chassis for easy access for cleaning or if
service is required
•ReverseCycleHeatPumpOperation
The 6100 Series heat pumps utilize the unique GE PTAC
heat pump operation to ensure a comfortable room.
The logic used by the units is the same logic used by
central system heat pumps to provide greater savings.