GE 6100 Air Conditioner User Manual


 
13
geappliances.com
Auxiliary Control Settings (cont)
Mode 3—Freeze Sentinel/Heat Sentinel
The default settings for Mode 3 are:
Heat Sentinel is off
Freeze Sentinel is on.
When Freeze Sentinel is activated, it automatically provides
heat without user interface. This helps to prevent plumbing
damage by turning the heater and indoor fan ON at 41ºF and
OFF at 46ºF.
When Heat Sentinel is activated, it automatically provides
cooling without user interface. This helps to prevent an
excessively hot room by turning the air conditioner ON at 85ºF
and OFF at 80ºF.
NOTE: These functions are active whenever the unit is plugged
in, even if the unit is in the STOP position.
Mode 4—Constant ON Fan
The default setting for Mode 4 is OFF.
Mode 5—Temperature Limiting
The default setting for Mode 5 is as follows:
Cool: 0 (60ºF to 85ºF)
Heat: 7 (60ºF to 85ºF)
Temperature limits—Cool Temperature limits—Heat
0 = 60°F to 85°F 0 = 60°F to 65°F
1 = 64°F to 85°F 1 = 60°F to 70°F
2 = 66°F to 85°F 2 = 60°F to 72°F
3 = 68°F to 85°F 3 = 60°F to 74°F
4 = 70°F to 85°F 4 = 60°F to 76°F
5 = 72°F to 85°F 5 = 60°F to 78°F
6 = 74°F to 85°F 6 = 60°F to 80°F
7 = 76°F to 85°F 7 = 60°F to 85°F
Mode 6—Remote Thermostat – Class 2
The default setting for Mode 6 is OFF.
Setting this mode to ON will allow the unit to operate
with a Class 2 Remote Control Wall Thermostat.
Mode 7—Duct Mode
The default setting for Mode 7 is OFF.
This setting is used when the unit is installed using a duct
adapter kit. If the unit is ducted, the Duct Mode needs to
be set to ON. This increases the fan speed to ensure proper
circulation.
Mode 8—All-Electric Heat (AZ6100 only)
The default setting for Mode 8 is OFF.
This electric heat option functions only on the 6100 model.
When this option is ON, heat pump operation is locked out,
causing the unit to provide only electric resistance heat.
Mode 9—Heat Boost (AZ6100 only)
The default setting for Mode 9 is OFF.
When Heat Boost is ON and outer temperatures are between
25ºF and 46ºF, heat pump only operation is locked out. This
setting is used to provide supplementary heat to the heat
pump operation by electric resistance heat in conditions
where the heat pump-only operation is not sufficient to
maintain a consistent, comfortable room temperature. NOTE:
Temperature Boost option should NOT be used with remote
thermostat operation. This will cause the unit to switch to
resistance heat when the outdoor temperature is 46ºF.