Stovax F40 Stove User Manual


 
4.1 Place the flame baffle onto the burner and push against the
rear tray lip. See diagram 6
4.2 Locate the rear panel against the spacer brackets and slide
down so that it locates on the ledge of the flame baffle. See
diagram 7
4.3 Locate the front coal between the heat shield and the flame
baffle so its ends sit flat on the burner skin. See diagram 8
4.4 Place five of the loose round coals on the front coal so they
lean against the flame baffle, in between the fingers. Place
the two rectangular coals against the reflector panels, one
either side, behind the front row of loose coals. See
diagram 9
4.5 Place four of the loose round coals behind the first row so
that they sit on the fingers, the two outer ones should touch
the rectangular coals. See diagram 10
4.6 Place the three remaining coals behind the centre row so
that they touch the back panel. See diagram 11
5.1 The stove is fitted with the Gazco Flue Sure System, which
will act to cut off the gas supply to the burners in the event
of incorrect operation of the flue. If the system acts to cut
off the gas supply, this indicates that there is insufficient flue
pull. If this occurs a minimum of 10 minutes should be
allowed before trying to relight. Continued operation of this
safety device means there may be a serious problem with
the flue system. A qualified gas engineer should inspect this.
Do not use the stove until an engineer says it is safe to
do so.
5. GAZCO FLUE SURE SYSTEM
4. FUEL BED ARRANGEMENT
7
USER INSTRUCTIONS
6
9
8
10
11
AR0359
7
AR0360
AR0361
AR0362
AR0363
AR0364