Stovax F40 Stove User Manual


 
1.1 Installation and servicing must be carried out by a
competent person in accordance with Gas Safety
(Installation and Use) Regulations 1998, the relevant British
Standards for Installation, appropriate Codes of Practice and
in accordance with the manufacturers instructions. It is
recommended that a CORGI registered engineer be used
for this purpose as they are approved by the HSE under the
above regulations.
1.2 This appliance is suitable for use in G.B. and I.E. using
Natural Gas at a supply pressure of 20mbar or LPG at a
supply pressure of 28mbar (Butane) or 37mbar (propane).
1.3 The installation shall also be completed in accordance with:
The Building Regulations issued by The Department of The
Environment.
The Building Standards (Scotland) Regulations issued by the
Scottish Development Department.
For Republic of Ireland, reference should be made to the
relevant standards governing installations (IS813:1996)
1.4 Read all these instructions before commencing installation.
1.5 This appliance must be installed in accordance with the
rules in force and only used in a sufficiently ventilated
space.
1.6 Ensure that curtains are not positioned above the stove, and
that there is at least a clearance of 300mm between the
sides of the stove and any curtains.
1.7 The manufacturer considers the full outer casing of this
stove to be a working surface. Therefore it will become hot
whilst in operation. A suitable guard is recommended to
protect young children, the aged and the infirm.
1.8 This stove must only be operated with the door secured
firmly in position. If any cracks appear in the glass the
appliance must not be used until the glass panel is replaced.
1.9 Do not attempt to burn rubbish in this stove.
1.10 Any combustible shelves or surrounding furniture must only
be fitted in accordance with the minimum dimensions
detailed in diagram 1.
1.11 Contact a competent service engineer to carry out relevant
spillage checks etc. following home improvements carried
out after installation of this stove (e.g. the fitting of double
glazing).
1.12 In all correspondence, please quote the appliance type and
serial number which can be found on the databadge at the
rear of the stove.
1.13 This product is guaranteed for 2 years from the date of
installation, as set out in the terms and conditions of sale
between Gazco and your local Gazco dealer. Please consult
with your local Gazco dealer if you have any questions. In
all correspondence always quote the model No. and serial
No. Please ensure the commissioning checklist is
completed by your installer, as this is a requirement of
your Guarantee.
2.1
To ignite the F40 Avanti
The Gazco F40 Avanti has a fully automatic battery
operated gas control which can be lit using the hand set or
touch pad. The touch pad is located on the lower front
panel of the appliance, behind the main door.
2.1.1 Before the fire can be lit the remote control must be in the
manual mode. See diagram 2. Refer to section 2.6 to
change to manual mode.
2.1.2 Press the ON / OFF button (11). The word ON appears in
the display (4).
2.1.3 Press the SET button (12). The pilot light should now light.
This should take about 10 seconds.
If the pilot fails to light press the ON / OFF button (11) and
then the SET button (12) then repeat the above sequence.
2.1.4 A single flame will appear on the display (1). When this has
stopped flashing, an audible click is heard. You are now
ready to adjust the flame height.
2. LIGHTING THE F40 AVANTI
WITH HAND SET
1. GENERAL
4
USER INSTRUCTIONS
1
AR1468
2
1: Flame display
2: Celsius display
3: Temperature display
4: On display
5: Off display
6: Low battery display
7: Clock display
8: Auto display
9: Manual display
10: UP button
11: ON/OFF button
12: SET button
13: DOWN button
AR1665
1
2
3
10
11
5
6
7
4
8
9
12
13