Estate Swing E-SC 1600 Garage Door Opener User Manual


 
Control Board Overview
7.1
Caution! Do not run 110V AC power direct to the board. This will cause permanent damage to both
boards and void your warrantee. Caution!
CN1 - Upper left hand corner of board, used for power and back up power.
VAC - terminals. The input terminals for the supplied 24V transformer. Polarity is not an
issue for this terminal.
+BAT, -BAT - terminals. Input terminals for the optional backup batteries. The battery
power coming in must be 24V DC. This can be achieved by running two 12V batteries in se-
ries. During normal operation, the unit keeps the batteries charged and the batteries begin op-
erating the unit if no power is being supplied through terminals VAC. Observe polarity on
these terminals.
+24, -24 - terminals. Accessories needing constant 24V power should be attached to these
terminals following the correct polarity. (Example: Alternate receiver, exit wand)
Continued on following page.