Estate Swing E-SC 1600 Garage Door Opener User Manual


 
Wiring The Operator Arm(s)
For the Master Operator: In terminal block CN2 insert the brown wire in APM1 and blue wire
in CHM1.
For the Slave Operator : In terminal block CN2 insert the blue wire in APM2 and brown wire
in CHM2.
*During the learning process, if either door begins to move in the open direction; stop
the door operator by removing power or tripping RESET switch. Then swap the
brown and blue wires, this will make the operator start in the right direction when
you restart the run time learning procedure.
4.6