Estate Swing E-SC 1600 Garage Door Opener User Manual


 
Operating Parameters Chart
Minimum Force
Medium-low Force
Medium-high Force
High Force
This parameter adjusts the sensitivity of the
electronic clutch system. The electronic clutch
system controls the anti-crushing auto-reverse
feature when a door in motion makes contact
with an obstacle.
1.5 Second Offset
3 Second Offset
6 Second Offset
10 Second Offset
This determines how long the second leaf will
pause before moving to allow the first leaf to
separate and avoid obstructing on the other
leaf.
If using a Single door opener system, the set-
ting will not affect your door.
Disabled
Enabled
This parameter turns auto-close on or off. The
pause time for the auto-close is set during
movement programming.
OPEN
A
Opens/Closes/Opens...
Opens/Stops/Closes/Stops...
This parameter determines what an OPEN A
terminal command will result in. d1 is recom-
mended for safety.
Disabled
Enabled
This parameter is for use with multiple door
users. If enabled, when the door is opening it
can not be reversed by another open signal.
FORCE
DELAY
AUTO-
RECLOSE
CONDO
Disabled
Enabled
OVER-
PUSH
This parameter is for use with electric door
locks. The door will briefly push further closed
before opening to allow the lock to release.
Flashing Lamp
90 Second Courtesy Light
LAMP
This parameter is to determine between a
flashing or steady lamp. If not using a lamp the
setting will not affect your door.
Continued on following page.