Estate Swing E-SC 1600 Garage Door Opener User Manual


 
4.8
Power
1. The Estate Swing E-SC 1602 comes with 1) 24V transformer. The transformer sup-
plied has 2 screw terminals to connect to. You may locate the transformer up to 1000’
away from the control board using wire ratings as specified below.
2. Insert the two wires from the transformer into the two VAC terminals on the control
board (CN1). The wires are not polarized, there is no positive or negative. Do not
splice the power cable wire.
Never run 110VAC power directly to the Estate Swing. This will destroy the Es-
tate Swing control board.
Never connect the power wire with the transformer
plugged in. Contact between the two lead wires, even
for a second, will destroy the transformer.
3. Plug the transformer into a 110 V AC outlet.
4. The transformer is not weather proof and must be
kept in a covered area. Plug covers are available from
your dealer, contact 1-800-640-GATE for a dealer in
your area.
5. Two 12V DC batteries may be run in series as
backup to the 24V transformer power. Running two
12V batteries in series creates a 24V system, you can-
not run them in parallel (see diagram to the left)
6. The power light located below the +24V and –24V
output terminals will be on if the power is connected
properly. If the light is off then power through the
transformer is not functioning properly and either the
unit has no power or is on battery backup. The light
stays off during battery backup.
0-99 Feet - Use 16 Gauge, 2 Conductor Stranded Direct Burial Wire
100-299 Feet - Use 14 Gauge, 2 Conductor Stranded Direct Burial Wire
300-599 Feet - Use 12 Gauge, 2 Conductor Stranded Direct Burial Wire
600-1000 Feet - Use 10 Gauge, 2 Conductor Stranded Direct Burial Wire