4.0 INSTRUMENT DESCRIPTION
THE SCOTT INSTRUMENTS MINI-SA INSTRUMENT is designed for use as
a personal monitor. The MINI-SA is equipped with a snap mounting clip for
ease of use. A break-away neck strap and rubber boot are also available.
All operations of the instrument are controlled by two push-button actuators
which are large enough to accommodate use with gloved hands. In each
menu screen, “PROMPTS” over each push-button define their use.
The SCOTT INSTRUMENTS MINI-SA INSTRUMENT case is constructed of
high impact resistant, flame retardant plastic. The push-button actuators
and the graphic display overlay are UV and chemical resistant.
The Graphic Liquid Crystal Display (LCD) provides continuous readings of
gas concentration as well as battery life remaining and other information.
Alarm conditions are signaled by an alarm legend on the graphic display, an
audible tone, a flashing light, and an internal vibration. Audible tones for
certain alarms can be suspended for thirty (30) second intervals while oth-
ers will continue until the unit is reset in an atmosphere that corresponds to
the preset safe values. Alarms can also be configured to be latching or
nonlatching. Latching alarms operate until acknowledged. Nonlatching
alarms clear automatically when the detected gas is on the safe side of the
alarm setting.